Operator Console Functions & Controls
Cage Unloading System
18
NEVER ATTEMPT TO SERVICE OR MAINTAIN THE UNLOADING
SYSTEM IF THE MAIN POWER SOURCE IS ENERGIZED. USE
PROPER LOCKOUT/TAGOUT PROCEDURES.
DANGER
SAFETY SHUTDOWN RESET BUTTON SWITCH
•
The safety shutdown reset push button switch is provided to prevent the system from operating right away
when the master power switch is turned “ON” and to reset the safety devices after a safety gate has been
opened and closed.
•
The operator must depress and release the switch to energize the relays that powered all electrical valves. This
action must be performed after the master power is turned “ON” and after one of the safety gates has been
opened and closed.
THE OPERATOR MUST WAIT 5 SECONDS AFTER
THE MASTER POWER SWITCH IS TURNED “ON”,
BEFORE DEPRESSING THE RESET BUTTON
SWITCH OR IT WILL NOT RESET THE SYSTEM.
NEVER DEPRESS THE RESET BUTTON SWITCH UNTIL YOU ARE
ABSOLUTELY SURE THERE IS NOBODY ON THE UNLOADING
SYSTEM AND/OR INSIDE THE SAFETY FENCE.
DANGER
BALL VALVE
•
The ball valve is used to disable the hydraulic components in the cage unloading system. This ball valve
should be locked out whenever an operator must be on the roller beds.