Operator Console Functions & Controls
Cage Unloading System
17
UNLOADING SYSTEM WITH CAGE WASHING SYSTEM
(See Figure 4B)
MASTER SWITCH
•
The master switch is a rotary switch that energizes the whole unloading system (including the hydraulic power
unit) when put in the “ON” position.
DOOR CLOSER SWITCH (if equipped)
POWER UNIT SWITCH
•
This three (3) position switch turns the pump #1 or pump #2 of the hydraulic power unit “ON” while in the “P#1”
or “P#2” position respectively. Both pumps are not energized if the power unit switch is in the “OFF” position.
•
We recommend using pump #1 as a primary. Pump #2 should be used one (1) day a week to make sure it is in
working condition in case pump #1 fails.
• The switch for the door closer must be in the “ON” position for this device to operate. In case of a malfunction,
the automatic door closer can be disabled by turning the door closer switch to the “OFF” position.
ALWAYS REPORT ANY MALFUNCTION TO YOUR SUPERVISOR
AND/OR THE MAINTENANCE MANAGER.
THE DOOR CLOSER IS AN AUTOMATIC DEVICE THAT IS OPERATED BY
A HYDRAULIC CYLINDER. DO NOT ATTEMPT TO SERVICE OR MAIN-
TAIN THE DOOR CLOSER UNLESS THE MAIN POWER SOURCE IS NOT
ENERGIZED. USE THE PROPER LOCKOUT/TAGOUT PROCEDURES.
DANGER