![Briggs & Stratton Twin Cylinder L-Head Repair Manual Download Page 32](http://html1.mh-extra.com/html/briggs-and-stratton/twin-cylinder-l-head/twin-cylinder-l-head_repair-manual_2811012032.webp)
2
13
Check Single Terminal Rotary Key Switch
1.
Disconnect stop switch wire from spade terminal.
2.
Connect one meter lead to spade terminal and
other lead to switch mounting surface or a good
ground.
3.
With key in “OFF” position. There should be conti-
nuity.
4.
Move key to “ON” position. There should be no
continuity, Fig. 35.
Fig. 35 – Check Rotary Stop Switch
OFF
ON
SPADE
TERMINAL
Check Multiple Terminal Rotary Key Switch –
Anti-Afterfire Circuit
1.
Disconnect equipment wiring harness from rotary
key switch.
2.
Connect one meter lead to battery terminal (B) and
other lead to carburetor solenoid terminal, (L or S).
3.
With key in “OFF” position there should be no
continuity, Fig. 36.
4.
With key in “RUN” and “START” position there
should be continuity.
Fig. 36 – Checking Anti-Afterfire Solenoid Circuit
OFF
START
S OR L
B
Check Multiple Terminal Rotary Key Switch –
Stop Switch Circuit
1.
Connect one meter lead to stop switch terminal
(M) and other lead to a good ground. If key switch
is mounted to an insulated panel, use ground
terminal (G), Fig. 37.
2.
With key in “OFF” position there should be conti-
nuity.
3.
With key in “RUN” and “START” position there
should be no continuity, Fig. 37.
NOTE: Ground terminal (G) is grounded to
switch case. If meter indicates continuity
when key is in “RUN” and “START” posi-
tion, switch is defective.
Fig. 37 – Checking Stop Switch Circuit