![Briggs & Stratton Twin Cylinder L-Head Repair Manual Download Page 31](http://html1.mh-extra.com/html/briggs-and-stratton/twin-cylinder-l-head/twin-cylinder-l-head_repair-manual_2811012031.webp)
2
12
Equipment To Test Stop Switches
The Digital Multimeter, Tool Tool #19357 or #19390 is
available from your Briggs & Stratton source of supply.
The meter may be used to measure Volts, Ohms, or
Amperes, Fig. 32.
Testing With Digital Multimeter
1.
Insert red test lead into
receptacle in
meter.
2.
Insert black test lead into
receptacle in
meter.
3.
Rotate selector to
position.
4.
When meter test leads are attached to switch termi-
nals, and switch is in “STOP” position, a continuous
tone indicates continuity. With switch in “RUN” posi-
tion, no tone indicates no continuity (incomplete cir-
cuit). An incomplete circuit will be displayed as “OL.”
NOTE: Contact surfaces must be free of paint,
rust or dirt.
Fig. 32 – Digital Multimeter
Check Single Terminal Toggle Switch
1.
Disconnect stop switch wire from spade terminal.
2.
Connect one meter lead to spade terminal and oth-
er lead to switch mounting surface or a good
ground.
3.
With switch in “OFF” position there should be
continuity.
4.
Move switch to “ON” position. There should be no
continuity, Fig. 33.
Fig. 33 – Checking Anti-Afterfire Solenoid Switch
V
Ω
Ω
ON
OFF
Check Multiple Terminal Toggle Switch
1.
Disconnect solenoid wire from carburetor spade
terminal.
2.
Connect one meter test lead to carburetor sole-
noid wire terminal and other lead to starter switch
terminal, Fig. 34.
3.
With switch in “ON” position there should be conti-
nuity.
4.
Move switch to “OFF” position. There should be no
continuity.
Fig. 34 – Checking Stop Switch
SOLENOID
WIRE
STARTER
TERMINAL
STOP
Summary of Contents for Twin Cylinder L-Head
Page 1: ...For Briggs Stratton Discount Parts Call 606 678 9623 or 606 561 4983 www mymowerparts com ...
Page 55: ......
Page 129: ......
Page 151: ......
Page 163: ......