![Briggs & Stratton SIMPLIPHI SPHI-B-4.9 Install And User Manual Download Page 4](http://html.mh-extra.com/html/briggs-and-stratton/simpliphi-sphi-b-4-9/simpliphi-sphi-b-4-9_install-and-user-manual_2810570004.webp)
E N E R G Y T R A K U S E R M A N U A L | 6
Creating Your Company’s
First Pro User Account
To begin using the EnergyTrak Mobile
App as a Pro, you will need to create your
company’s first Pro user account: a Pro
Admin. For improved security, creating your
first Pro Admin account is controlled by
Briggs & Stratton.
In order to create your first Pro Admin account, contact Briggs
& Stratton at 800-759-2744 or
This manual step is only required to create your first Pro Admin account. You will then be able to use
that account to create additional Pro Admin users and Pro Technician users (more information on user
types in the below section titled EnergyTrak for Pros). Once your Pro Admin account has been created,
you will receive instructions via email for logging in to your account on the EnergyTrak app.
Getting Started with
EnergyTrak for Pros
Complete this
initial step well
in advance
of your first
SimpliPHI ESS
installation.
>>>
EnergyTrak Gateway Installation
BA
TTE
RY
DE
VI
CE
(-)
(+)
CAN
LA
N
U
SB
INTERNET
BMS
RS
-232
INVERTER COMMS BOARD
48V
GATEWAY ENCLOSURE
BOUNDARY
GATEWAY
DC-DC
3A FUSE
TERMINAL
BLOCK
(+)
(-)
BA
TTE
RY
120 OHM
TERMINATING
RESISTOR
V OUT
24V
V IN
24V
18AWG
POWER
GW-10
GW-12
GW-5
GW-4
GW-6
GW-3
GW-9
GW-1
GW-8
GW-2
GW-7
GW-11
Not Included (Customer Provided)
GW-8 Battery CAN Bus Ethernet Cable
(Cat-5e or Cat-6)1
GW-9 Inverter RS-232 Ethernet Cable
(Cat-5e or Cat-6, 30 meters or less)
GW-10 Inverter CAN Bus Ethernet Cable
(Cat-5e or Cat-6, 100 meters or less)
GW-11 Local Area Network Ethernet Cable
(Cat-5e or Cat-6, 100 meters or less)
GW-12 Battery to Gateway Enclosure Electrical
Wires (two (2) wires; 18 AWG)2
Required Cables and Adapters
Included with the EnergyTrak Gateway
GW-1
Crossover Cable Adapter
GW-2
CAN to RJ45 Adapter
GW-3 DB9 to RJ45 RS-232 Adapter
GW-4 Gateway to Power Supply DC Power Cables
GW-5 Fuse DC Jumper Cable (pre-installed)
GW-6 USB to DB9 RS-232 Adapter
GW-7
Battery Power to Gateway Enclosure Ring Terminals
(two (2) units)
Installation Diagram
1
The overall length of all ethernet cables used across the entire battery bank CAN bus cannot exceed 100 meters; this includes the ethernet cable (GW-8) between the EnergyTrak Gateway
and the Battery it is connected to, and all ethernet cables running from battery to battery (not pictured here)
WARNING:
Connecting
the EnergyTrak Gateway to
the SimpliPHI ESS requires
physical contact with the
SimpliPHI 6kW Inverter and
SimpliPHI 4.9kWh Battery
that could result in shock
or serious injury. Follow
proper safety precautions as laid out in
the SimpliPHI 6kW Inverter Installation
Manual and SimpliPHI 4.9kWh Battery
Installation Manual.
>>>