E N E R G Y T R A K U S E R M A N U A L | 1 8
Operating Profile Descriptions
Grid-Tied Backup
Parameter
Setting
Solar Distribution Priority
Battery > Load > Grid
Enable Charging
Enabled
Enable AC Charging
Enabled
Enable feed to Utility
Enabled
Enable discharge to Load when PV present
Disabled
Enable discharge to Load when PV absent
Disabled
Grid-Tied Backup with Time-of-Use
Parameter
Setting
Solar Distribution Priority: On-Peak
Load > Battery > Grid
Solar Distribution Priority: Off-Peak
Battery > Load > Grid
Enable Charging
Enabled
Enable AC Charging
Enabled
Enable feed to Utility
Disabled
Enable discharge to Load when PV present
Enabled
Enable discharge to Load when PV absent
Enabled
Grid-Tied Zero Export
Parameter
Setting
Solar Distribution Priority
Load > Battery
Enable Charging
Enabled
Enable AC Charging
Enabled
Enable feed to Utility
Disabled
Enable discharge to Load when PV present
Enabled
Enable discharge to Load when PV absent
Enabled
Grid-Tied Solar
Parameter
Setting
Solar Distribution Priority
Grid
Enable Charging
Disabled
Enable AC Charging
Disabled
Enable feed to Utility
Enabled
Enable discharge to Load when PV present
Disabled
Enable discharge to Load when PV absent
Disabled
Off-Grid
Parameter
Setting
Solar Distribution Priority
Load > Battery
Enable Charging
Enabled
Enable AC Charging
Disabled
Enable feed to Utility
Disabled
Enable discharge to Load when PV present
Enabled
Enable discharge to Load when PV absent
Enabled
E N E R G Y T R A K U S E R M A N U A L | 1 9