background image

4

Briggs & Stratton Power Products Manual Transfer Switch

Installation and Owner’s Manual

INTRODUCTION

Thank you for your purchase of this Briggs & Stratton
Power Products Manual Transfer Switch.This product is
intended for use with Briggs & Stratton Home Standby
Generator sets ONLY.This is an optional home standby
system which provides an alternate source of electric
power and to serve loads such as heating, refrigeration
systems, and communication systems that, when stopped
during any power outage, could cause discomfort or the
like.This product DOES NOT qualify for emergency
standby as defined by NFPA 70 (NEC).

Briggs and Stratton Power Products (BSPP) has made every
effort to provide for a safe, streamlined and cost-effective
installation. Each installation is unique; it is impossible for
BSPP to know and advise of all conceivable procedures and
methods by which installation might be performed, nor the
potential hazards associated with those methods. For these
reasons,

Only licensed electrical contractors should

install transfer switches. Installations must

strictly comply with all applicable federal,

state and local codes, standards and

regulations.

Your BSPP Transfer Switch is supplied with this combined
“Installation and Owner’s Manual”.This is an important
document and should be retained by the owner after the
installation has been completed.

Every effort has been expended to make sure that the
information in this manual is both accurate and current.
However, the manufacturer reserves the right to change,
alter or otherwise improve the system at any time without
prior notice.

For the Home or Business Owner

To help you make informed choices and communicate
effectively with your installation contractor(s),

Read and understand the

Owner Orientation Section of this manual

BEFORE contracting or starting
your transfer switch installation.

To arrange for proper installation, contact the store at
which you purchased your BSPP Transfer Switch, your
dealer, or your utility power provider.

The Transfer Switch Warranty is VOID

unless the system is installed by a 

licensed electrical professional.

For the Installing Dealer/Contractor

 Check federal, state and local codes for questions on

installation.

 If you need more information about the transfer switch,

call 1-800-743-4115, between 8:00 AM and 5:00 PM CT.

Owner Orientation

The illustrations are for typical circumstances and are
meant to familiarize you with the installation options
available with your transfer switch.

Local codes, appearance, and distances are the factors that
must be considered when negotiating with an installation
professional. As the distance from the existing electrical
service increases, compensation in wiring materials must be
allowed for.This is necessary to comply with local codes
and overcome electrical voltage drops.

The factors mentioned above will have a direct effect
on the overall price of your transfer switch installation.

NOTE: Your installer must check local codes AND obtain
permits before installing the system.

• Read and follow the instructions given in this manual.

• Follow a regular schedule in caring for and using your

transfer switch, as specified in the manual.

Installer Responsibilities

• Read and observe the safety rules.

• Read and follow the instructions given in this manual.

• Check federal, state and local codes.

Summary of Contents for 50A NEMA 1

Page 1: ...uda es justa un momento lejos Vous avez des questions Vous n avez pas besoin d aller loin pour trouver de l aide Call Transfer Switch Helpline Llamada L nea Directa de Interruptor de Transferencia App...

Page 2: ...Dealer Contractor 4 Owner Orientation 4 Installer Responsibilities 4 Equipment Description 5 INSTALLATION 5 Unpacking 5 Delivery Inspection 5 Shipment Contents 5 Mounting Dimensions 5 ESSENTIAL CIRCU...

Page 3: ...der the transfer switch unsafe DO NOT touch bare wires or receptacles DO NOT use transfer switch with worn frayed bare or otherwise damaged wiring DO NOT handle electrical cords while standing in wate...

Page 4: ...any time without prior notice For the Home or Business Owner To help you make informed choices and communicate effectively with your installation contractor s Read and understand the Owner Orientatio...

Page 5: ...he same time If utility line power is restored while generator power is being used there will be no affect on the generator or transfer switch components When utility power is restored follow the inst...

Page 6: ...ansfer Switch is installed after the main distribution panel The Manual Transfer Switch has a load rating of 60 Amps This is the maximum load rating of the essential loads All wiring must conform to n...

Page 7: ...Figure 3 Discuss layout suggestions changes with the owner before beginning the system installation process Power Wiring Interconnections All wiring must be the proper size properly supported of appro...

Page 8: ...Typical Installation Diagram for Transfer Switch MODEL 071003 MODEL 071002 Main Distribution Panel Ground Bus Neutral Bus To Generator Generator Connection Utility Connection Main Distribution Panel G...

Page 9: ...TILITY SUPPLY breaker to ON position 4 Turn ON branch circuit breakers one at a time Specifications UL 1008 Listed Transfer Switch Model 071002 Enclosure NEMA 1 Maximum Load Circuit from Load Center 6...

Page 10: ...n and Owner s Manual TRANSFER SWITCH SERVICE PARTS MODEL 071002 NEMA 1 Part Description 195566GS KIT HRDWR NEMA1 SRV 195568GS KIT DOOR NEMA1 SRV MODEL 071003 NEMA 3R Part Description 195567GS KIT HRDW...

Page 11: ...11 Briggs Stratton Power Products Manual Transfer Switch Installation and Owner s Manual NOTES...

Page 12: ...12 Briggs Stratton Power Products Manual Transfer Switch Installation and Owner s Manual NOTES...

Page 13: ...le to this warranty Electric Powered Pressure Washers used for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROO...

Page 14: ...16 Responsabilit s de l Installateur 16 Description de l quipement 17 INSTALLATION 17 D ballage 17 V rification de la Livraison 17 Contenu de la Bo te 17 Dimensions d Installation 17 ISOLATION DES CI...

Page 15: ...tallation de ce syst me laquelle doit se conformer strictement aux codes aux normes et aux r glementations applicables AVERTISSEMENT NE touchez PAS les fils d nud s ou les bo tiers N utilisez PAS le c...

Page 16: ...soin la section Conseils au propri taire dans le pr sent guide avant de contracter un entrepreneur ou de commencer l installation de votre commutateur de transfert Pour assurer une installation ad qua...

Page 17: ...alimentation de service alors que l alimentation de la g n ratrice est utilis e n aura aucune incidence sur la g n ratrice Lorsque l alimentation de service est r tablie suivez les instruction de la...

Page 18: ...pal La charge nominale du commutateur de transfert manuel est de 60 Amp res Il s agit de la limite de charge pour les charges essentielles Tout le c blage doit tre conforme au national de l lectricit...

Page 19: ...Alimentation Tout le c blage doit tre d un gabarit appropri bien fix et prot g par des conduits Effectuez les raccords suivants entre le commutateur de transfert le panneau de distribution principal...

Page 20: ...t Manuel MOD LE 071003 MOD LE 071002 Panneau de Distribution Principal Barre de mise la terre Barre neutre La G n ratrice Branchement de la g n ratrice Branchement de l lectricit de service Panneau de...

Page 21: ...r d interdiction m canique et r glez le disjoncteur Utility Supply la position ON 4 Mettez SOUS TENSION un la fois les disjoncteurs de circuit de branchement Caract ristiques Commutateur de transfert...

Page 22: ...22 Commutateur de transfert manuel Briggs Stratton Power Products Guide d installation et d utilisation REMARQUES...

Page 23: ...POUR EXERCER LA GARANTIE SUR TOUT PRODUIT FABRIQU PAR BRIGGS STRATTON IL N EST PAS N CESSAIRE DE L ENREGISTRER CONSERVEZ LE RE U COMME PREUVE D ACHAT SI LORS D UNE R CLAMATION DE GARANTIE VOUS NE POU...

Page 24: ...el Propietario 26 Responsabilidades del Instalador 26 Descripci n del Equipo 27 INSTALACI N 27 Desempaque 27 Inspecci n al Momento de la Entrega 27 Contenido de la Caja 27 Dimensiones de Montaje 27 AI...

Page 25: ...lar este sistema Dicha instalaci n debe cumplir estrictamente con los c digos las regulaciones y las normas correspondientes ADVERTENCIA NO toque los alambres pelados o recept culos NO use un interrup...

Page 26: ...tar o iniciar la instalaci n de su conmutador de transferencia Para coordinar y organizar una instalaci n adecuada consulte al comercio en el cual adquiri su interruptor de transferencia Briggs Stratt...

Page 27: ...uministro del generador se est utilizando el generador no se ver afectado Cuando se establezca el suministro de servicio general siga las instrucciones especificadas en Funcionamiento del sistema INST...

Page 28: ...panel de distribuci n principal El interruptor de transferencia manual tiene un valor nominal de carga de 60 Amperios Este es el valor nominal m ximo para las cargas fundamentales Todas las conexione...

Page 29: ...bi n debe estar protegido mediante un conducto aprobado por el NEC Realice las conexiones siguientes entre el conectador el panel principal de distribuci n y el generador Figura 12 de la p gina siguie...

Page 30: ...Panel de Distribuci n Principal Barra conductora Ground tierra Barra conductora NEUTRAL neutro Al Generador Conexi n al generador Conexi n de la compa a proveedora de electricidad Panel de Distribuci...

Page 31: ...or marcado como UTILITY SUPPLY hacia la posici n de ACTIVADO 4 ACTIVE los disyuntores derivados de a uno por vez Especificaciones Interruptor de transferencia UL 1008 Modelo 071002 Revestimiento NEMA...

Page 32: ...el equipo que presente defectos de materiales y o mano de obra Los gastos de transporte de las piezas enviadas para reparar o sustituir conforme a los t rminos de esta garant a correr n a cargo del co...

Reviews: