7
15
Fig. 27
−
Typical 12 V Wiring Diagram
ALTERNATOR
SOLENOID
STOP
SWITCH
STARTER
MOTOR
+
-
12 VOLT
BATTERY
REGULATOR
RECTIFIER
HEAD
LIGHTS
6
KEY SWITCH
SOLENOID TAB
TERMINAL
BATTERY
TERMINAL
STARTER
TERMINAL
AC
OUTPUT
WIRES
HEAD
LIGHT
SWITCH
5
4
3
2
1
DC OUTPUT
WIRE
ANTI-AFTERFIRE
SOLENOID
Checking Battery
1. Physical check
−
clean if necessary.
a. Corrosion
b. Dirt
c. Terminal and clamps
(secure
−
good conditions)
2. Bring battery to full charge.
Fig. 28
−
Checking 12 V Battery Cells
(Lead Acid, Wet Cell, With Fill Caps)
CHECK ALL CELLS AF-
TER CHARGING
USE TEMPERATURE
COMPENSATED
HYDROMETER
REPLACE IF READINGS
ARE BELOW 1.225 OR IF
CELLS VARY BY MORE
THAN .50
DO NOT EXCEED CHARGE RATE OF 1/10 AMPERE
FOR EVERY AMPERE OF BATTERY RATING. Consult
battery manufacturer for charging recommendations.
Overcharging may cause battery failure.
a. Use a taper charger (automatically reduces charge
rate).
b. Fill battery cells with distilled water or tap water
(unless maintenance free type) after charging (for
batteries that have been in service). NOTE: If bat-
tery gets “hot” to the touch or is spitting acid (gas-
sing) excessively, unplug charger periodically.
3. With battery fully charged, check specific gravity read-
ings (unless maintenance free type) of each cell with a
Battery Hydrometer and record readings (Fig. 28).
All readings should be above 1.250 (compensating for
temperature). If specific gravity readings varied .50 or if
ALL cells read less than 1.225, replace battery.
TSM
Summary of Contents for 405777 Series