background image

 

5

Installation

We sincerely appreciate your patronage. For this reason, 

we have made significant effort to provide for a safe, 

streamlined and cost-effective installation. Because each 

installation is unique, it is impossible to know of and advise 

the trade of all conceivable procedures and methods by 

which installation might be achieved. Neither could we know 

of possible hazards and/or the results of each method or 

procedure. For these reasons,

Only current licensed electrical should attempt system 

installations. Installations must strictly comply with all 

applicable codes, industry standards and regulations.

Your equipment is supplied with this combined “Installation 

and Operator’s Manual”. This is an important document and 

should be retained by the owner after the installation has 

been completed.
Every effort has been made to make sure that the information 

in this manual is both accurate and current. However, the 

manufacturer reserves the right to change, alter or otherwise 

improve the system at any time without prior notice.

Home Owner Responsibilities

To help you make informed choices and communicate 

effectively with your installation contractor(s),

Read and understand 

Owner Orientation

 before contracting 

or starting your equipment installation.

To arrange for proper installation, contact the store at which 

you purchased your equipment, your dealer, or your utility 

power provider.

The equipment warranty is VOID unless the system is 

installed by licensed electrical professionals.

Owner Orientation

The illustrations provided are for typical circumstances and 

are meant to familiarize you with the installation options 

available with your system.
Local codes, appearance, and distances are the factors that 

must be considered when negotiating with an installation 

professional. As the distance from the existing electrical 

service increases, compensation in wiring materials must 

be allowed for. This is necessary to comply with local codes 

and overcome electrical voltage drops.

These factors will have a direct effect on the overall price 

of your equipment installation.
NOTE

: Your installer must check local codes AND obtain 

permits before installing the system.

  •  Read and follow the instructions given in this manual.
  •  Follow a regular schedule in caring for and using your 

equipment, as specified in this manual.

Installing Dealer/Contractor Responsibilities

  •  Read and observe the safety rules.
  •  Read and follow the instructions given in this manual.
  •  The installer may need to provide appropriate rated 

contactors based on loads to be controlled.

  •  Check federal, state and local codes and authority 

having jurisdiction, for questions on installation.

  •  Ensure generator is not overloaded with selected loads.

If you need more information about the transfer switch, call 

(800) 743-4115, between 8:00 AM and 5:00 PM CT.

Equipment Description

The transfer switch is designed to transfer the selected loads 

found in normal residential installations when used with the 

supervisory contacts provided. The load is connected either 

to utility power (normal) or home standby power (generator). 

The transfer switch monitors utility and generator voltages 

and will automatically connect to the appropriate source 

of power.
These switches make it easy for a licensed electrician to 

complete a home standby installation. Service conduit and 

conductors can be wired directly from the hour-meter to the 

transfer switch. A separate disconnect and associated wiring 

are not required when installed per applicable federal, state 

and local codes, standards and regulations.
Major components of the transfer switch are a 2 pole utility 

disconnect circuit breaker, a 2 pole generator disconnect 

circuit breaker, a 2 pole double throw transfer switch, control 

circuit board, fused utility terminals and interconnecting 

wiring. The control board also has two inputs for current 

transformers that sense generator current. These 

components are housed in a NEMA 3R enclosure that is 

suitable for both indoor and outdoor installations.
The transfer switch is solenoid-operated from utility or 

generator inputs and contain suitable mechanical and 

electrical interlock switches to eliminate the possibility of 

connecting the utility service to the generator output. It 

has ratings capable of switching full utility power into the 

residence. In addition, a manual override lever is provided 

for the transfer function.
The control board has active circuits sensing utility and 

generator voltages. It creates a signal for the generator 

start-up, switch transfer and retransfer when utility is 

restored. The control board also contains red and green 

LED’s indicating the power sources available and two 

relay operated contacts that provide supervisory control of 

external loads.

Summary of Contents for 200 AMP AUTOMATIC TRANSFER

Page 1: ...200 Amp Automatic Transfer Switch with Service Disconnect and AC Control Module Installation Operator s Manual...

Page 2: ...ise of all conceivable procedures and methods by which installation might be achieved We do not know all possible hazards and or the results of each possible method or procedure It is important that y...

Page 3: ...on 5 Owner Orientation 5 Installing Dealer Contractor Responsibilities 5 Mounting Guidelines 6 Power Wiring Interconnections 7 Controls 10 Operation 10 Maintenance 11 Troubleshooting 12 Schematic Diag...

Page 4: ...es standards and regulations WARNING Certain components in this product and related accessories contain chemicals known to the State of California to cause cancer birth defects or other reproductive h...

Page 5: ...for and using your equipment as specified in this manual Installing Dealer Contractor Responsibilities Read and observe the safety rules Read and follow the instructions given in this manual The inst...

Page 6: ...sure must be installed with minimum NEMA 3R hardware for conduit connections Level and plumb the enclosure This can be done by placing washers between the enclosure and the mounting surface NEVER inst...

Page 7: ...ral terminal 12 Connect copper conductor from transfer switch GND terminal to generator control panel GROUND terminal NOTE Assure generator equipment grounding conductor is connected per applicable fe...

Page 8: ...o Utility Ground Terminal Load Connection Main Distribution Panel Neutral Terminal Supervisory Contacts Generator Connection Utility Connection Wireways CT CT UTILITY 240VAC to Generator T R and GND t...

Page 9: ...als B B on control module are rated for 1 Amp 125 VAC and installer supplied contactor to control a large load such as an electric hot water heater Contacts are connected in series with the contactor...

Page 10: ...power to transfer switch contactor to On position 2 Install 15 Amp fuse in generator s control panel 3 Set generator s circuit breaker to On position 4 Set generator s system switch to AUTO position...

Page 11: ...t once a month Access to transfer switch must not be obstructed Keep 3 feet 92 cm clearance around transfer switch Check for an accumulation of dirt moisture and or corrosion on and around the enclosu...

Page 12: ...ngine should stop after 1 minute Generator or supervised loads air conditioner etc are operating improperly when generator is supplying power 1 A A or B B contacts not operating correctly 2 Too much l...

Page 13: ...13 Schematic Diagram...

Page 14: ...14 BRIGGSandSTRATTON COM Wiring Diagram...

Page 15: ...SE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD ABOUT YOUR WARRANTY We welcome warranty repair and apologize to yo...

Page 16: ...s Poles 2 Frequency 60 Hz Fault Current Rating 25 000 RMS Symmetrical Amperes Supervisory Contacts Rating A A Terminals 24 Volt AC B B Terminals 1 Amp 125 Volt AC Pilot Duty Normal Operating Range 20...

Page 17: ...Interruptor de transferencia autom tica de 200 amperios con m dulo de control de energ a el ctrica de CA Manual de instalaci n y del operario...

Page 18: ...ci n profesional antes de utilizarse Consulte las instrucciones sobre los procedimientos de instalaci n en la secci n Instalaci n del presente manual Los conectador s lo deben ser instalados por elect...

Page 19: ...5 Orientaci n al propietario 5 Responsabilidades del distribuidor t cnico instalador 5 Pautas de montaje 6 Interconexi n de los cables de alimentaci n 7 Controles 10 Funcionamiento 10 Mantenimiento 1...

Page 20: ...onentes en este producto y los accesorios relacionados contienen sustancias qu micas declaradas cancer genas causantes de malformaciones y otros defectos cong nitos por el Estado de California L vese...

Page 21: ...strucciones que se indican en este manual Siga un plan regular de cuidado y uso del equipo como se indica en este manual Responsabilidades del distribuidor t cnico instalador Lea y respete las normas...

Page 22: ...1 Transformadores de corriente 2 No incluye Cable y conducto de conexi n Herramientas equipos especiales diversos Pautas de montaje El conectador autom tico est encerrado en una caja tipo 3R NEMA que...

Page 23: ...s del transformador de corriente a los terminales CT1 y CT2 del m dulo de control 11 Conecte el conductor de cobre del terminal neutro del conectador al terminal neutro del panel de control del genera...

Page 24: ...al Barra conductora Ground tierra Barra conductora NEUTRAL neutro Al generador Terminales NEUTRAL neutro A la red p blica Contactos de supervisi n Conexi n de la carga Orejetas de conexi n a tierra GN...

Page 25: ...el control de supervisi n de grandes cargas conectadas al generador Ejemplo acondicionador de aire calentador de agua etc Las cargas podr n funcionar siempre que la potencia del generador sea suficien...

Page 26: ...tensi n de la red p blica al contactor del conectador en la posici n ON cerrado 2 Instale el fusible de 15 A en el panel de control del generador 3 Ponga el disyuntor del generador en la posici n ON 4...

Page 27: ...ncipalmente el mantenimiento consiste en la limpieza del conectador Lleve a cabo un examen visual al menos una vez al mes La v a de acceso al conectador debe permanecer libre de obst culos Deje un esp...

Page 28: ...a detenerse despu s de 1 minutos Las cargas supervisadas acondicionador de aire etc no funcionan cuando se utiliza la red el ctrica 1 Los contactos A A o B B no funcionan correctamente 2 La carga del...

Page 29: ...JEFFERSON WI EE UU El per odo de garant a comienza en la fecha de compra del primer consumidor o usuario comercial final y se prolonga durante el tiempo especificado en la siguiente tabla Uso del cons...

Page 30: ...c a 250 Volts Polos 2 Frecuencia 60 Hz Valor nominal de la corriente conexi n a tierra 25 000 Amperios eficaces sim trica Valor nominal de los contactos de supervisi n A A 24 V CA contactos de superv...

Page 31: ...200 A Commutateur de transfert automatique avec AC Power Control Module Manuel d installation et d utilisation...

Page 32: ...installation possibles De plus nous ne connaissons pas tous les dangers et ou r sultats potentiels de chaque m thode ou proc dure Il est important de bien lire et comprendre enti rement ces directives...

Page 33: ...onseils au propri taire 5 Responsabilit s du d taillant de l entrepreneur charg de l installation 5 Directives d assemblage 6 Interconnexions du c blage d alimentation 7 Commandes 10 Mode d utilisatio...

Page 34: ...connus par l tat de la Californie comme causant des cancers des malformations cong nitales ou d autres probl mes de reproduction Nettoyez vous les mains apr s la manipulation Choc lectrique Lisez le m...

Page 35: ...idence directe sur le prix total de l installation de votre quipement REMARQUE Votre installateur est tenu de v rifier les codes locaux ET d obtenir les permis requis avant de proc der l installation...

Page 36: ...n communiquez avec le transporteur pour conna tre les proc dures de r clamation Les pi ces manquantes ou endommag es ne sont pas garanties Contenu de l envoi Commutateur de transfert automatique 1 Man...

Page 37: ...teur de courant avant que la connexion ne soit effectu e 10 Branchez les fils du transformateur de courant aux bornes CT1 et CT2 sur le module de commande 11 Branchez le conducteur en cuivre partir de...

Page 38: ...l Barre de mise la terre Barre neutre la g n ratrice Terminaux neutre vers l alimentation Contacts de contr le Raccordement des charges Terminaux de mise la terre Branchement de la g n ratrice Branche...

Page 39: ...re raccords l usage du client Deux ensembles de contacts normalement ferm s sont disponibles Ils sont activ s lorsque la g n ratrice est mise en marche Ils peuvent servir au contr le d importantes cha...

Page 40: ...g n ratrice est la position AUTO placez le disjoncteur de l alimentation de service alimentant le contacteur du commutateur de transfert la position OFF Au bout de quelques minutes la g n ratrice s a...

Page 41: ...Off La s quence automatique commencera Pour revenir l alimentation de service r glez l interrupteur de d branchement sur On Panne de l alimentation de service Le capteur de tension de service d tecte...

Page 42: ...ROBL MES CAUSE SOLUTION Le commutateur de transfert automatique ne transf re pas la g n ratrice 1 Le disjoncteur de la g n ratrice est ouvert 2 La tension de la g n ratrice n est pas ad quate 1 R arme...

Page 43: ...Power Products Group LLC r parera ou remplacera sans frais toutes pi ces d quipement d fectueuses comportant un vice de mat riau ou un d faut de fabrication ou les deux En vertu de la pr sente garant...

Page 44: ...nce nominale 25 000 Amp res Sym triques RMS Valeur nominale des contacts de contr le A A 24 Volt c a contacts de contr le B B 1 amp re 125 Volt c a r gime de fonctionnement asservi Plage d utilisation...

Reviews: