background image

 

15

Warranty

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC  TRANSFER SWITCH OWNER WARRANTY POLICY

LIMITED WARRANTY

Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material or 
workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This 
warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest Authorized Service Dealer in 
our dealer locator map at BRIGGSandSTRATTON.COM.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW.  ANY AND ALL IMPLIED WARRANTIES ARE 
EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some 
states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion or limitation 
of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you 
may also have other rights which vary from state to state or country to country.

The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time stated in the 
table above. “Consumer use” means personal residential household use by a retail consumer. “Commercial use” means all other uses, including use for 
commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter be considered as commercial use for 
purposes of this warranty. Equipment used for prime power in place of utility are not applicable to this warranty.

NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF OF PURCHASE 
RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED, THE MANUFACTURING 

DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.

ABOUT YOUR WARRANTY

We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most warranty 
repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not apply if 
equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation. Similarly, the 
warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered or modified. During 
the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal 
use and service. This warranty will not cover the following repairs and equipment:

• 

Normal Wea

r: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not cover 

repair when normal use has exhausted the life of a part or the equipment.

• 

Installation and Maintenance

: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation 

or alteration and modification, misuse, negligence, accident, overloading, improper maintenance, repair or storage so as, in our judgment, to adversely 
affect its performance and reliability. This warranty also does not cover normal maintenance such as adjustments, cleaning and fuse replacement.

• 

Other Exclusions:

 This warranty excludes wear items or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or 

improper servicing. Accessory parts are excluded from the product warranty. This warranty excludes failures due to acts of God and other force 
majeure events beyond the manufacturers control. Also excluded is used, reconditioned, and demonstration equipment.  

198180E, Rev. C, 12/31/200

6

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC

JEFFERSON, WI, USA

Effective November 1, 2005 replaces all undated Warranties and all Warranties dated before November 1, 2005

3 years
None

Consumer Use
Commercial Use

WARRANTY PERIOD

Summary of Contents for 200 AMP AUTOMATIC TRANSFER

Page 1: ...200 Amp Automatic Transfer Switch with Service Disconnect and AC Control Module Installation Operator s Manual...

Page 2: ...ise of all conceivable procedures and methods by which installation might be achieved We do not know all possible hazards and or the results of each possible method or procedure It is important that y...

Page 3: ...on 5 Owner Orientation 5 Installing Dealer Contractor Responsibilities 5 Mounting Guidelines 6 Power Wiring Interconnections 7 Controls 10 Operation 10 Maintenance 11 Troubleshooting 12 Schematic Diag...

Page 4: ...es standards and regulations WARNING Certain components in this product and related accessories contain chemicals known to the State of California to cause cancer birth defects or other reproductive h...

Page 5: ...for and using your equipment as specified in this manual Installing Dealer Contractor Responsibilities Read and observe the safety rules Read and follow the instructions given in this manual The inst...

Page 6: ...sure must be installed with minimum NEMA 3R hardware for conduit connections Level and plumb the enclosure This can be done by placing washers between the enclosure and the mounting surface NEVER inst...

Page 7: ...ral terminal 12 Connect copper conductor from transfer switch GND terminal to generator control panel GROUND terminal NOTE Assure generator equipment grounding conductor is connected per applicable fe...

Page 8: ...o Utility Ground Terminal Load Connection Main Distribution Panel Neutral Terminal Supervisory Contacts Generator Connection Utility Connection Wireways CT CT UTILITY 240VAC to Generator T R and GND t...

Page 9: ...als B B on control module are rated for 1 Amp 125 VAC and installer supplied contactor to control a large load such as an electric hot water heater Contacts are connected in series with the contactor...

Page 10: ...power to transfer switch contactor to On position 2 Install 15 Amp fuse in generator s control panel 3 Set generator s circuit breaker to On position 4 Set generator s system switch to AUTO position...

Page 11: ...t once a month Access to transfer switch must not be obstructed Keep 3 feet 92 cm clearance around transfer switch Check for an accumulation of dirt moisture and or corrosion on and around the enclosu...

Page 12: ...ngine should stop after 1 minute Generator or supervised loads air conditioner etc are operating improperly when generator is supplying power 1 A A or B B contacts not operating correctly 2 Too much l...

Page 13: ...13 Schematic Diagram...

Page 14: ...14 BRIGGSandSTRATTON COM Wiring Diagram...

Page 15: ...SE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD ABOUT YOUR WARRANTY We welcome warranty repair and apologize to yo...

Page 16: ...s Poles 2 Frequency 60 Hz Fault Current Rating 25 000 RMS Symmetrical Amperes Supervisory Contacts Rating A A Terminals 24 Volt AC B B Terminals 1 Amp 125 Volt AC Pilot Duty Normal Operating Range 20...

Page 17: ...Interruptor de transferencia autom tica de 200 amperios con m dulo de control de energ a el ctrica de CA Manual de instalaci n y del operario...

Page 18: ...ci n profesional antes de utilizarse Consulte las instrucciones sobre los procedimientos de instalaci n en la secci n Instalaci n del presente manual Los conectador s lo deben ser instalados por elect...

Page 19: ...5 Orientaci n al propietario 5 Responsabilidades del distribuidor t cnico instalador 5 Pautas de montaje 6 Interconexi n de los cables de alimentaci n 7 Controles 10 Funcionamiento 10 Mantenimiento 1...

Page 20: ...onentes en este producto y los accesorios relacionados contienen sustancias qu micas declaradas cancer genas causantes de malformaciones y otros defectos cong nitos por el Estado de California L vese...

Page 21: ...strucciones que se indican en este manual Siga un plan regular de cuidado y uso del equipo como se indica en este manual Responsabilidades del distribuidor t cnico instalador Lea y respete las normas...

Page 22: ...1 Transformadores de corriente 2 No incluye Cable y conducto de conexi n Herramientas equipos especiales diversos Pautas de montaje El conectador autom tico est encerrado en una caja tipo 3R NEMA que...

Page 23: ...s del transformador de corriente a los terminales CT1 y CT2 del m dulo de control 11 Conecte el conductor de cobre del terminal neutro del conectador al terminal neutro del panel de control del genera...

Page 24: ...al Barra conductora Ground tierra Barra conductora NEUTRAL neutro Al generador Terminales NEUTRAL neutro A la red p blica Contactos de supervisi n Conexi n de la carga Orejetas de conexi n a tierra GN...

Page 25: ...el control de supervisi n de grandes cargas conectadas al generador Ejemplo acondicionador de aire calentador de agua etc Las cargas podr n funcionar siempre que la potencia del generador sea suficien...

Page 26: ...tensi n de la red p blica al contactor del conectador en la posici n ON cerrado 2 Instale el fusible de 15 A en el panel de control del generador 3 Ponga el disyuntor del generador en la posici n ON 4...

Page 27: ...ncipalmente el mantenimiento consiste en la limpieza del conectador Lleve a cabo un examen visual al menos una vez al mes La v a de acceso al conectador debe permanecer libre de obst culos Deje un esp...

Page 28: ...a detenerse despu s de 1 minutos Las cargas supervisadas acondicionador de aire etc no funcionan cuando se utiliza la red el ctrica 1 Los contactos A A o B B no funcionan correctamente 2 La carga del...

Page 29: ...JEFFERSON WI EE UU El per odo de garant a comienza en la fecha de compra del primer consumidor o usuario comercial final y se prolonga durante el tiempo especificado en la siguiente tabla Uso del cons...

Page 30: ...c a 250 Volts Polos 2 Frecuencia 60 Hz Valor nominal de la corriente conexi n a tierra 25 000 Amperios eficaces sim trica Valor nominal de los contactos de supervisi n A A 24 V CA contactos de superv...

Page 31: ...200 A Commutateur de transfert automatique avec AC Power Control Module Manuel d installation et d utilisation...

Page 32: ...installation possibles De plus nous ne connaissons pas tous les dangers et ou r sultats potentiels de chaque m thode ou proc dure Il est important de bien lire et comprendre enti rement ces directives...

Page 33: ...onseils au propri taire 5 Responsabilit s du d taillant de l entrepreneur charg de l installation 5 Directives d assemblage 6 Interconnexions du c blage d alimentation 7 Commandes 10 Mode d utilisatio...

Page 34: ...connus par l tat de la Californie comme causant des cancers des malformations cong nitales ou d autres probl mes de reproduction Nettoyez vous les mains apr s la manipulation Choc lectrique Lisez le m...

Page 35: ...idence directe sur le prix total de l installation de votre quipement REMARQUE Votre installateur est tenu de v rifier les codes locaux ET d obtenir les permis requis avant de proc der l installation...

Page 36: ...n communiquez avec le transporteur pour conna tre les proc dures de r clamation Les pi ces manquantes ou endommag es ne sont pas garanties Contenu de l envoi Commutateur de transfert automatique 1 Man...

Page 37: ...teur de courant avant que la connexion ne soit effectu e 10 Branchez les fils du transformateur de courant aux bornes CT1 et CT2 sur le module de commande 11 Branchez le conducteur en cuivre partir de...

Page 38: ...l Barre de mise la terre Barre neutre la g n ratrice Terminaux neutre vers l alimentation Contacts de contr le Raccordement des charges Terminaux de mise la terre Branchement de la g n ratrice Branche...

Page 39: ...re raccords l usage du client Deux ensembles de contacts normalement ferm s sont disponibles Ils sont activ s lorsque la g n ratrice est mise en marche Ils peuvent servir au contr le d importantes cha...

Page 40: ...g n ratrice est la position AUTO placez le disjoncteur de l alimentation de service alimentant le contacteur du commutateur de transfert la position OFF Au bout de quelques minutes la g n ratrice s a...

Page 41: ...Off La s quence automatique commencera Pour revenir l alimentation de service r glez l interrupteur de d branchement sur On Panne de l alimentation de service Le capteur de tension de service d tecte...

Page 42: ...ROBL MES CAUSE SOLUTION Le commutateur de transfert automatique ne transf re pas la g n ratrice 1 Le disjoncteur de la g n ratrice est ouvert 2 La tension de la g n ratrice n est pas ad quate 1 R arme...

Page 43: ...Power Products Group LLC r parera ou remplacera sans frais toutes pi ces d quipement d fectueuses comportant un vice de mat riau ou un d faut de fabrication ou les deux En vertu de la pr sente garant...

Page 44: ...nce nominale 25 000 Amp res Sym triques RMS Valeur nominale des contacts de contr le A A 24 Volt c a contacts de contr le B B 1 amp re 125 Volt c a r gime de fonctionnement asservi Plage d utilisation...