Installation Checklist
Carbon Monoxide (CO) Detector
Carbon Monoxide (CO) detector(s) installed and in
working order.
Smoke detector(s) installed and in working order.
Placement
Required permits have been obtained.
Generator is placed in an area free from Carbon
Monoxide (CO) buildup. See
Carbon Monoxide
Hazard Safety Placement Requirements.
Generator is placed in an area free from potential water
damage
.
Generator is placed in an area free from utility and other
home systems
.
Generator is placed in a debris free zone
.
Generator is placed on flat ground with provisions for
water drainage.
Fuel
Generator is connected to fuel source with flexible fuel
line, has no fuel leaks and conforms to national rules
and regulations of the respective country.
See
Gaseous Fuel System.
Proper fuel pressure has been measured with all gas
appliances operating. See
Gaseous Fuel System
.
Fuel system has been configured for the proper fuel
supply: Natural gas (NG) or liquefied petroleum (LP).
See
Fuel Conversion.
Fuel type: (circle one) NG LP
Fuel pipe size used: (circle one) 19mm 25mm 32mm
38mm
Fuel pressure at fuel inlet port with generator on and at
full load and all gas appliances turned on and operating
____________________.
Electrical
Generator is connected to Automatic Transfer Switch.
See
Generator AC Connection System
.
Generator is grounded. See
Grounding the
Generator
.
Generator is connected to the transfer switch with the
specified wiring. See
Utility Circuit Connection
and
Communication Connections.
Generator is connected to the transfer switch with the
specified wiring. #0.82 mm² twisted pair wiring from the
generator control panel to the transfer switch is installed
in a separate conduit from high voltage wires unless
the insulation rating on all wiring is rated for 600V. See
Communication Connections
.
Dipswitches in most transfer switches must be set
to correspond to the wattage of the generator.
See
Transfer Switch Operator/Installation Manual
.
Operation
Cold weather kit is installed in temperatures below -1°C.
See
Cold Weather Kit.
Correct battery type is installed and fully charged. See
Final Installation Considerations.
Generator engine oil level is at full mark. See
Final
Installation Considerations
.
All circuit breakers are in the ON position (Generator and
Transfer Switch).
Utility was shut off to test the operation of generator
and transfer switch. Note any service codes and make
corrections as required.
AC Voltage Output___________________________.
Frequency Output___________________________.
Owner Information
Name: _______________________________________
Address: _____________________________________
Phone/e-mail:__________________________________
Generator Information
Generator Model: _______________________________
Generator Serial Number: ________________________
Installing Contractor Information
Name: _______________________________________
Address: _____________________________________
Phone/FAX: ___________________________________
Electrician: ___________________________________
Signature: ____________________________________
Plumber: _____________________________________
Signature: ____________________________________
Inspector Information
Name: _______________________________________
Address: _____________________________________
_____________________________________________
Title: _________________________________________
Inspection Date: ________________________________
This generator has been installed per the manufacturer’s
instructions:
Installing Contractor Signature: _________________________
Date: _____________________________________________
Proper installation of the generator requires the completion of the following tasks. Fill out the information below and give to
the user.