19
Troubleshooting
Problem
Cause
Correction
Engine is running, but no AC output is
available.
1. Circuitbreakeropenordefective.
. Faultingenerator.
3. Poorwiringconnectionsor
defectivetransferswitch.
1. Resetorreplacecircuitbreaker.
. Contactlocalservicefacility.
3. Checkandrepair.
Engine runs good at no-load but “bogs
down” when loads are connected.
1. Shortcircuitinaconnectedload.
. Generatorisoverloaded.
3. Shortedgeneratorcircuit.
4. FuelPressureisincorrect.
5. Naturalgasfuelmixtureisincorrect.
6. Kinkedfuellinebetweenregulator
andengine.
1. Disconnectshortedelectricalload.
. See
Essential Circuits
.
3. Contactlocalservicefacility.
4. See
Gaseous Fuel System
inthe
InstallationManual.
5. See
Gaseous Fuel System
inthe
InstallationManual.
6. Removekinkinfuelline.Replaceif
necessary.
Engine will not start; or starts and runs
rough.
1. 15Ampfusemissingorblown.
. Fuelsupplyturnedoff,restrictedor
depleted.
3. Failedbattery.
4. Cloggedairfilter.
1. Install(new)15Ampfuse.See
System Control Panel
.
. Openfuelvalve(s);checkpropane
tank.
3. Replacebattery.
4. Cleanorreplaceairfilter.
Engine shuts down during operation.
1. Fuelsupplyturnedoff,restrictedor
depleted.
. Faultindicatorblinking.
1. Checkfuelvalves,fillpropanetank.
. Countblinksandreferto
Fault
Detection System
.
Loss of power on essential circuits.
1. Generatorcircuitbreakerisopen.
. Transferswitchproblems.
1. Resetcircuitbreaker.
. Seethetransferswitchmanual.
Summary of Contents for 10000 Watt
Page 18: ...18 BRIGGSandSTRATTON COM...
Page 20: ...20 BRIGGSandSTRATTON COM Schematic...
Page 21: ...21 Wiring Diagram...
Page 23: ...23...
Page 25: ...Home Generator Systems Manual del Operario 10000 Watt Sistema generador dom stico...
Page 45: ...21...
Page 47: ...Home Generator Systems Manuel de l Utilisation 10000 Watt Groupe lectrog ne...
Page 67: ...21...