![BRG DuraTime HP Installation And Operation Manual Download Page 59](http://html.mh-extra.com/html/brg/duratime-hp/duratime-hp_installation-and-operation-manual_2809923059.webp)
59
First Menu
Level
Mode Number
Second
Menu
Level
Value
Range
Mode Description and Instructions
When an array of clocks use frame rotation and each clock is to display a different,
synchronized frame, a value of 2-24 may be used to determine what frame is used at
startup. All clocks would need to be powered up at the same time, or a single clock
can be powered up with the knowledge up what frame it will begin with.
37
21
Display
format
number
Counter Display Mode – Most Significant Four Digits
Default counter display mode for the most significant four digits of an eight digit
counter value (default=40). See also Modes 36 and 37-15.
37
22
1-24
Alpha Time Character Time Zone Source
(0-24) - 0 = disabled (default) - This mode is used to specify which time zone is to be
used for special alpha time characters. Mode 51-6 is used to assign multiple unique
time zone offsets to special alpha characters. Mode 37-22 must be 0 for Mode 51-6
to take effect; otherwise, Mode 37-22 will override any Mode 51-6 settings. See
mode 51-1 for a list of special alpha time characters. See also Mode 51-6.
37
23
0-3
Serial Data Bit Length
0=Com1(SR/ST)=8 bit, Com2(GPS)=8 bit, (default)
1=Com1(SR/ST)=7 bit, Com2(GPS)=7 bit,
2=Com1(SR/ST)=8 bit, Com2(GPS)=7 bit,
3=Com1(SR/ST)=7 bit, Com2(GPS)=8 bit
37
24
1-24
Alarm Schedule Time Zone Source
1 (default) This mode determines which time zone will be used for alarm schedules.
37
25
0,1
Display Colon on Date Display Mode 53
0=disable(default),
1=enable
37
28
0,1
Enable/Disable Analog Time Zone Master Clock
0=Disabled (default)
1=Enabled
The mode reconfigures the clock as a Time Zone Master clock for digital wall clocks.
37
29
0-99
Control Button Lockout and Addressable Clock Function
0=Disabled (default)
1=Disable the Mode button x minutes after the last button press. Up and Down
button work normally. See also Mode 32-55.
2=Disable the Mode, Up and Down buttons x minutes after the last button press.
Mode 32-49 determines the delay period. To enable the buttons, press and hold the
Mode button until four one’s or four two’s appear (about 5 seconds), then release the
mode button. Pressing the Up and Down buttons simultaneously will also enable the
buttons.
3=Disable the Mode, Up and Down buttons x minutes after the last button press.
Mode 32-49 determines the delay period. Pressing the Up and Down buttons together
will not enable the buttons. To enable the buttons, press and hold the Mode button
until four one’s or four two’s appear (about 5 seconds), then release the mode button.