38
First Menu
Level
Mode Number
Second
Menu
Level
Value
Range
Mode Description and Instructions
If 32-37=1, then pressing the timer control button while the timer is stopped or
paused, will return to real time. Set mode 32-4=2 when using this mode.
32
8
0-2
UTC/Local Time Serial Receive
0 = expects to receive UTC time on RS-422, Sets hours, minutes and seconds (no
date) when receiving IRIG-B/SMPTE/ESE time codes.
1 = expects to receive local time on RS-422. This mode is used when the slaves are
to display the same time as the master or computer. (default) Sets minutes and
seconds only (no hours or date) when receiving IRIG-B/SMPTE/ESE time codes.
2 = This mode is used to cancel daylight savings time when sending time from a
computer to a time zone display. Set Mode 45-5 to the time zone of the time
received. For example, if CDMA is used to receive the time, set Mode 45-5 to the
local offset from UTC. Also, set Mode 32-65 to the local daylight saving rule in
version 4.28 and later. The default is U.S. daylight saving time.
See also Mode 45-5 to set the incoming time zone offset.
32
9
0,1
UTC/Local Time Serial Transmit
0 = transmits UTC time on RS-422,
1 = transmits local time on RS-422. (default)
32
10
0,1
Timer/Counter Alarm Control
0 = enable counter/timer alarm,
1 = disable counter/timer alarm.
32
11
0,1,2
Mode and Display Format Switching Over Serial Sync Line
0 = disable auto mode and format switching from serial data received (default)
1 = enable operating mode and display format switching
2 = enable operating mode switching only
5 = Low speed IR remote control test. Use the control buttons to set this Mode 32-
11=5, not the remote.
A value of 1 allows time packets received to change the operating mode (Mode 14)
and the display formats for zones 1 and 2 (Modes 20-1 and 20-2). A value of 2
changes the operating mode, but does not change the display format. This setting is
recommended when using the clock with a Time Commander timer. This allows the
Time Commander to drive displays with a variety of display configurations.
32
12
0-3
Serial Sync Transmission
0 = disable serial sync output (default),
1 = enable serial sync output with variable delay in real time only.
2= enable serial sync output with variable delay.
3=enable serial sync output with variable delay in real time.
4=transmit time sync out SR/ST port only to control radio paging transmitter If
Mode 37-59=0 then 35 byte data will also be sent out the GPS port once per minute.
In this case, also set Mode 32-15=7.
5= transmit time sync out GPS port only to control radio paging transmitter If Mode
37-59=1 then 35 byte data will also be sent out the SR/ST port once per minute. In
this case, also set Mode 32-15=7.