35
First Menu
Level
Mode Number
Second
Menu
Level
Value
Range
Mode Description and Instructions
10=Sat/Sun,
11=Mon/Wed/Fri,
12=Tue/Thu,
13=Tue-Sat.,
14=Mon-Thu,
15=Mon-Sat
Display and time source number 1 is used for alarm activation in multi-display
clocks.
In addition to day-of-the-week combination codes, Mode 29 also accepts any day
combination. A value greater than 128 is treated as a binary command. Days of the
week are assigned the following binary numbers: Mon=1, Tue=2, Wed=4, Thu=8,
Fri=16, Sat=32 and Sun=64. Any combination of days may be selected by adding
their assigned numbers together and then adding 128 to that value. For example, if
Mon, Wed and Fri are required, then the value would be 149 (1+4+16+128=149).
30
1-99
alarm
setting
0-99 seconds
Individual Alarm Output Duration
This mode controls individual alarm output duration. Mode 5 controls the output
duration for all alarm times. Mode 30 overrides Mode 5 for specific alarm duration
values. For example, this mode may be used when one alarm tone needs to be longer
or shorter than other alarm tones. A value of zero allows Mode 5 to control alarm
output duration. For extended alarm duration beyond 99 seconds, see Mode 45-15.
This mode is a multiplier for the alarm duration setting. It allows an alarm duration up
to 12 days. See also Mode 32-13, Mode 34 for pulse alarm operation, and Mode 37-
56 for wireless alarm systems.
31
1-24
0-7
Individual Numeric Zone Color
0=disables (default)
This value determines the individual numeric zone color. This setting overrides
Mode 6, default zone color. Available colors: 1=green, 2=red, 3=blue, 4=yellow,
5=magenta, 6=cyan, 7=white.
See Also:
Mode 6 – default zone color,
Mode 51- individual alpha character color,
Mode 25 - individual display intensity control,
Mode 32-14 - auto brightness,
Mode 37-83 - alpha character default intensity,
Mode 51-7 - alpha individual intensity.
32
1
0-3
Sync Status
General purpose clock sync indicator using decimal point or blinking colon,
0=disable (default),
1=enable. While enabled, the PM indicator will flicker at the top of the minute if the
displayed time is in sync with a radio sync pulse, wired sync data, GPS time
receivers.
2= if SR sync signals received, then change the display mode to 3 (blinking colon).