The Breeze
11
Models: 3030, 3030SR, 3030EX, 3040 and 3040SR
How to Check a Triac: (3040 models only)
1. Make sure to first unplug the machine.
2. Set the multimeter for ohms or continuity.
3. Disconnect all machine leads from the triac.
4. Connect the positive ohmmeter lead to MT2 and the negative lead to MT1. The ohmmeter
should indicate no continuity (OL) through the triac.
5. Using a separate jumper lead, connect the gate of the triac to MT2. The ohmmeter should
indicate continuity. (less than 100 ohms)
6. Reconnect the triac so MT1 is connected to the positive ohmmeter lead and the negative
lead to MT2. The ohmmeter should indicate no continuity (OL) through the triac.
7. Using a separate jumper lead, connect the gate of the triac to MT2. The ohmmeter should
indicate continuity. (less than 100 ohms)
Summary of Contents for 3030
Page 2: ...The Breeze 2 Models 3030 3030SR 3030EX 3040 and 3040SR ...
Page 10: ...The Breeze 10 Models 3030 3030SR 3030EX 3040 and 3040SR MAINTENANCE INSTRUCTIONS ...
Page 22: ...The Breeze 22 Models 3030 3030SR 3030EX 3040 and 3040SR ELECTRICAL SCHEMATIC EXPORT 3030EX ...
Page 23: ...The Breeze 23 Models 3030 3030SR 3030EX 3040 and 3040SR Electrical Schematic 3040 3040SR ...