CLEARANCES AND HEIGHT REQUIREMENTS

WARNING:

THE DIMENSIONS SHOWN ARE MINIMUM CLEARANCES 
TO MAINTAIN IN INSTALLING THIS HEATER. LEFT AND 
RIGHT CLEARANCES ARE DETERMINED WHEN FACING THE 
FRONT OF THE HEATER. FOLLOW THESE INSTRUCTIONS 
CAREFULLY TO ENSURE SAFE INSTALLATION. FAILURE TO 
FOLLOW INSTRUCTIONS EXACTLY CAN CREATE A FIRE 
HAZARD. THE APPLIANCE CANNOT BE INSTALLED ON 
A CARPET, TILE OR OTHER COMBUSTIBLE MATERIAL. THE 
APPLIANCE SHALL BE INSTALLED ON A NONCOMBUSTIBLE 
MATERIAL PANEL EXTENDING THE FULL WIDTH AND 

DEPTH OF THE APPLIANCE. 

D

Minimum to

Side Wall

 

E

Minimum to

Side Wall

A

Front View

Ceiling

Mantel

Side 

Wall

F

Minimum

36"

in Front 

C

B

Side View

Ceiling

G

G

Corner 

Installation

D

Minimum

to Either

Side Wall 

F Minimum 

Wall 

Installation

A Min Ceiling From Floor

72”

B Mantel Clearance From Top 

Of Unit

Max. Protrusion 12”

C

Min. Height

18”

D

Side Measured From

Right

2” 

E

Left

2” 

F

Rear Measured From Back

1”

G Corner Measured From Top Corners

1/2”

Summary of Contents for BH32VF

Page 1: ...lease read this manual BEFORE installing and operating this unit Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SME...

Page 2: ...OSION AND ASPHYXIATION HAZARD IMPROPER ADJUSTMENT ALTERATION SERVICE MAINTENANCE OR INSTALLATION OF THIS HEATER OR ITS CONTROLS CAN CAUSE DEATH OR SERIOUS INJURY READ AND FOLLOW INSTRUCTIONS AND PRECA...

Page 3: ...___________________________ If no Date of inspection of existing venting system ______________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Inst...

Page 4: ...fessionals for the installation of hard wired carbon monoxide detectors In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic the hard wire...

Page 5: ...ar the appliance 5 Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater 6 Installation and repair should be done by a qualified service person 7...

Page 6: ...y causing headaches or eye or lung irritation This is a normal and temporary occurrence The initial break in operation should last two to three hours with the burner at the highest setting Provide max...

Page 7: ...duce supply pressure to a maximum of 13 0 w c for LP systems IGNITION CONTROLS Piezo ignitor allows ignition of the pilot without the use of matches Millivolt control has four 4 positions OFF All gas...

Page 8: ...S TECHNICIAN WILL NEED FOR INSTALLATION You must have the following items available before proceeding with installation External regulator for Propane LPG or high pressure natural gas 1 to 2 psi syste...

Page 9: ...LLED ON A CARPET TILE OR OTHER COMBUSTIBLE MATERIAL THE APPLIANCE SHALL BE INSTALLED ON A NONCOMBUSTIBLE MATERIAL PANEL EXTENDING THE FULL WIDTH AND DEPTH OF THE APPLIANCE D Minimum to Side Wall E Min...

Page 10: ...IGHT REQUIREMENTS INSTALLATION CAUTION THE APPLIANCE IS VERY HEAVY THE ASSISTANCE FROM A SECOND PERSON IS STRONGLY SUGGESTED PLEASE USE PROPER LIFTING TECHNIQUE WHEN POSITIONING THE APPLIANCE FOR ASSE...

Page 11: ...s removed for pictorial purposes only Screen UP BACK Side of unit is removed for pictorial purposes only 5 Remove the log box from inside the unit Lift the unit off the pallet NOTE Make sure to lift t...

Page 12: ...t model Pipe Coupling To Heater Valve Gas Supply Inlet Manual Shutoff Valve Pipe Stainless Flexible Tube Locations that the Pressure Tapping Point May Be Installed ELECTRICAL WIRING MILLIVOLT The mill...

Page 13: ...ntacts Meter Reading Should Be A Complete System 2 3 Closed Closed B Thermopile 1 2 Open Open On Off Switch Wall Switch Optional Wall Switch or Remote ODS Pilot Millivolt Valve CONNECTION 1 TP TH 2 TP...

Page 14: ...Support Bracket PILO T OFF Left Bottom Log 2 Back Log 1 Right Top Log 5 PILO T OFF Left Bottom Log 2 Back Log 1 Top Left Log 4 Right Top Log 5 PILO T OFF Right Top Log 5 Top Left Log 4 Log Support Br...

Page 15: ...he burner pan Cover the entire section of holes ports Replacement of loose Glowing Wool must be purchased from the original manufacturer and application of excess loose material may adversely affect t...

Page 16: ...nued use For Your Safety Read Before Lighting WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTION EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE A This appli...

Page 17: ...ing Pilot OFF ON ST1179 on off swit Control Cover Plate for Millivolt Hi Lo Control Ignitor Pilot Control On Off Switch Located on Side o Stove Pilot OFF ON ST1179 on off switch Control Cover Plate fo...

Page 18: ...ulation of lint at air intake holes Verify flame pattern and log placement for proper operation Verify smooth and responsive ignition of main burner and rear burner OPERATION CONTACT YOUR DEALER OR IN...

Page 19: ...spray glues etc Ventilate room Stop using odor causing products while heater is running Gas leak Locate and correct all leaks Initial burn off Ventilate room and turn unit on high until odor is gone...

Page 20: ...burner orifice Slight smoke or odor during initial operation Burner orifice is clogged or damaged Clean burner or replace burner orifice Burner is damaged Replace burner Gas regulator defective Replac...

Page 21: ...embly 1 9 892537 7 Control Panel 1 10 892537 8 Control Cover 1 11 40854 Leg 1 12 610120 Front Screen Assy 1 13 40859 Ash Bar 1 14 40858 Control Cover 1 15 40855 Front 1 16 89921 ODS Pilot Assembly NAT...

Page 22: ..._______________ Engineer Name __________________________________ License No ______________________________________ Company _______________________________________ Telephone No ________________________...

Page 23: ...2021 Breckwell Hearth 23 NOTES...

Page 24: ...24 2021 Breckwell Hearth NOTES...

Reviews: