• To switch the night mode off touch/press the button
(18) « » again.
LOW WATeR LeveL InDICATIOn
• When the water tank (2) is empty, the unit will be
switched off, there will be sound signals, and the
symbol « » will be flashing in the operation mode
icons row (19).
• Switch the unit off with the button (13) « », remove
the nozzle (1) and the water tank (2). Fill the water
tank (2) with water. Place the filled water tank (2) on
the body (7) and then install the nozzle (1).
• Switch the unit on for further operation.
CLeAnInG AnD MAInTenAnCe
- pour the water out of the water tank (2) and the
process chamber (6)
- wash and clean the process chamber (6) and the
sprayer
- wash the water tank (2)
- dry the air humidifier thoroughly and take it away
for storage.
WeekLY CARe
• Once a week wash the water tank (2), the process
chamber (6) and the sprayer with warm water and
neutral detergent and rinse thoroughly with water.
• Before cleaning the process chamber (6) remove the
heating element protective lid (5).
• Add some detergent drops on the sprayer and wait
for several minutes. Remove the deposits from the
sprayer surface with a brush.
•
note:
— you can use scale removal substances for
electric kettles as a cleaning agent for the process
chamber (6) and the sprayer strictly following the
instruction.
• Remove the grid (9), clean the filter from dust, install
the filter and the grid (9) back to their place.
• Clean the unit body (7) with a slightly damp cloth and
then wipe the body (7) dry.
• Do not immerse the unit body (7), the power cord and
the power plug into water or other liquids. Provide
that no liquid gets inside the unit body (7).
• Do not use solvents or abrasives to clean the surface
of the body (7) and the water tank (2).
STORAGe
• Clean the air humidifier before taking it away for
storage, make sure that the air humidifier parts are
dry, pack the air humidifier in the original package.
• Do not store the unit with remaining water in the tank
(2) and the process chamber (6).
• Keep the air humidifier in a dry cool place out of
reach of children and disabled persons.
TROUBLeS AnD TROUBLeSHOOTInG
Malfunction
Possible
causes
Troubleshooting
The indicator
doesn't light up, no
mist release
No supply
voltage or the
mains socket is
damaged.
Connect the unit to the
mains.
Plug another, known
good appliance to the
socket to make sure
that the socket works
properly.
The indicator is
glowing red, no mist
release.
The water tank
is empty.
Fill the water tank with
water.
Released mist has
foreign smell.
First use of the
unit.
Drain the water from the
water tank and leave it
open for several hours
in a cool place.
Stale water in
the tank.
Unplug the unit, remove
the water tank, pour
out the water, wash the
tank and fill it with clean
water.
Low mist release
intensity
Mineral scale on
the sprayer.
Unplug the unit and
clean the sprayer.
DeLIveRY SeT
1.
Air humidifier assembled — 1 pc.
2.
Remote control — 1 pc.
3.
Instruction manual — 1 pc.
TeCHnICAL SPeCIFICATIOnS
• Power supply: 220-240 V, ~50-60 Hz
• Rated input power: 40 W
• Water tank capacity: 4.5 L
• Water discharge: ≥ 350 ml/h
• Humidified area: up to 25 sq.m.
WARnInG!
Always switch the air humidifier off and unplug it
before maintenance works or cleaning.
• Hard water causes the appearance of mineral scale
inside the process chamber (6), on the sprayer and
in the water tank (2); mineral scale leads to improper
operation of the humidifier.
• It is recommended to clean the process chamber (6)
and the sprayer weekly, and to change water in the
water tank (2).
• If you are not going to use the air humidifier for a
long time: