BRAVE SlimDP
–
User and service manual 29
Parameter
Value
Meaning
Basic
38
r p
relay
r
control during incoming call
(0/1)
11 21
r
– relay number relay number [1 in SlimDP]
p
– parameter whether it is allowed
p=1
or disallowed
p=0
to control relay
during incoming call.
To prohibit „control‟ during an incoming call, for use with relay 2 in mode 1 for
controlling a garage door, so the electronics open the garage door and the car
passing through the door, closes the door. Then control from the phone could
result in a permanently opened door (i.e. the door doesn‟t close because car
didn‟t enter).
Parameter
Value
Meaning
Basic
30
r zz
time
zz
[sec] between impulses for
switching on relay
r
2 impulses- time
t2
(01-99)
105 205
r
– relay number relay number [1 in SlimDP , 2 in Slimey]
zz
– time t2 between first and second impulse for switching on relay 1 [2
spaces 00-99], where time 00 means 0,5sec
Parametr Value
Description
Default
3#0
p
p = 1 enabled / disabled p = 0 connection
code relay COSW (0/1)
0
p
– turns on transmission serial code to activate the first relay.
CAUTION
- at activation this function never connect to the circuit electric lock
without board COSW - code relay - threatens to destroy the relay in Brave
communicator!
The following codes may be the same or different for the resolution switching
on multiple parallel connected relay code.
Parametr Value
Description
Default
3#1
abcd
activation code 1 pulse from buttons
(0000-1111)
0000
abcd
–
Brave sends a serial code for the code relay (COSW) after
evaluation code from keys (keyboard) namely for 1 pulse