WARNING

 • Do not handle the power cord with a wet hand. Doing so may result in an electric shock.
 •

 

Do not spill water or a chemical solution onto or into the motor handpiece or battery 

charger. Doing so may result in fire or electric shock due to a short-circuit or breakage 
due to rust formation.

 • Do not disassemble or alter the motor handpiece.
 • Do not drop the motor handpiece or battery charger. Place the battery charger on a flat and  

stable place.

 • Should the battery fluid leak and get into your eyes, immediately wash eyes thoroughly with 

clean water and see your doctor. Failure to do so may result in loss of sight.

 • Should the battery fluid leak and adhere to skin or clothing, immediately wash the exposed 

skin thoroughly with clean water and completely wash away the fluid. Failure to do so may 
result in skin trouble.

 • If you should notice a battery fluid leak within the motor handpiece, deformation of the 

motor-handpiece casing or partial discoloring, immediately stop use and contact Brasseler USA.

 • If the product will not be used for a long period of time, remove the batteries to avoid fluid leak. 

 • Exercise sufficient care in using the product by giving patient safety first priority
 • The product is to be used for only dental treatment by qualified personnel.
 • Use commercially available batteries recommended by Brasseler USA.

Read carefully the instruction manual by the battery manufacturer before use.

 • Do not use a bent, damaged, deformed or non-ISO-conforming bur, as this may result in personal 

injury due to its sudden breaking or flying off during rotation.

 • Do not use or leave the product in a high-temperature environment such as under strong direct 

sunlight, in a car under a blazing sun, by a fire, or near a stove.

 • Check the product before use by rotating it, paying attention to looseness, vibration, noise and 

temperature (heat generation). If any abnormal condition is found even slightly at that time, 
immediately stop use and contact Brasseler USA.

 • Always clean the shank of the bur before installing. Allowing dirt to enter the chuck could cause 

loss of concentricity and deterioration of chucking force.

 • Before changing the head or bur, turn off the power of the motor handpiece.

Changing with the power on may cause unintended rotation by accidental touching of the 
ON/OFF switch.

 • When inserting the motor handpiece into the battery charger, position the handpiece correctly. 

Pushing it into the charger forcibly in the incorrect position may cause damage.

 • Be careful not to drop conductive parts such as wires and safety pins into the charging terminal 

area of the battery charger.

 • Before inserting the motor handpiece into the battery charger, wipe it clean. If the charging 

terminal area becomes dirty, rust formation may prevent charging, or result in short-circuit.

 • Do not lubricate the motor handpiece.
 • Do not heat sterilize the motor handpiece. Do not autoclave.

 

 

 

   CAUTION

Summary of Contents for HygienePro Air

Page 1: ...afety be sure to follow them Cautions for handling and operation Classification DANGER WARNING CAUTION NOTICE Degree of Danger or Damage and Seriousness Explains an instruction where death or serious...

Page 2: ...efully the instruction manual by the battery manufacturer before use Do not use a bent damaged deformed or non ISO conforming bur as this may result in personal injury due to its sudden breaking or fl...

Page 3: ...es may recover after repeating complete discharge and full charge a few fimes If you do not use the product for a long period of time remove the batteries from the motor handpiece NOTICE Compact body...

Page 4: ...Fig 1 3 Packaging Contents Battery charger Motor handpiece Power cord F type spray nozzle Motor cap Contra head DPA 4 For Disposable Prophy Angles 4 1 Reduction...

Page 5: ...rns on the power and re pressing and holding the switch for 2 seconds or longer turns off the power In addition by pressing the switch when the power is on the rotation speed can be selected Power Rot...

Page 6: ...Fig 6 If the power lamp or charge lamp flashes turn on the power switch once again If they still flash contact Brasseler USA Charge lamp Battery lamp Caution Connect to AC120V power supply only Volta...

Page 7: ...l only turn off when the batteries are drained to a certain low voltage level Auto Power Off Function Fig 7 If the Battery lamp flashes at no load during rotation this means that the battery is at a l...

Page 8: ...hey click When removing the contra head pull it straight out Fig 8 3 Changing Contra Head Make certain that the contra head is securely assembled to the motor handpiece Motor handpiece Positioning pin...

Page 9: ...ave pouch to keep it clean until you use it Sterilize the contra head only For sterilization we recommend the autoclave sterilization method Sterilization is required first time you use and after each...

Page 10: ...g may be different nickel metal hydride batteries 600 700 mAh nominal 1 2V Or Ni Cad batteries 200 300 mAh nominal 1 2V However please take note that the operating time shortens because of their capac...

Page 11: ...move old batteries 6 Insert new batteries according to the polarity marking in the battery box A mix up between the plus and minus sides will not allow operation of the handpiece 7 Attach the battery...

Page 12: ...w the discharge completion voltage Battery drain The battery voltage dropped below the voltage near discharge completion Temporary voltage dropped due to battery drain or heavy loading Non operational...

Page 13: ...tteries Turn on the power Recharge the batteries Recharge the batteries Insert and remove the motor handpiece into from the battery charger several times Turn on the power of the battery charger Inser...

Page 14: ...ByYour Side in Dentistry One Brasseler Boulevard Savannah GA 31419 To order call 800 841 4522 or fax 888 610 1937 Visit our website www BrasselerUSA com 08 08 005 M...

Reviews: