background image

B - C r e a m   &   B - c r e a m   H D

36

ENGLISH

If one of these alarm codes appears on the display, please refer to Appendix 1: Possible Problems and their Solutions.

9  FIRMWARE VERSIONS CHRONOLOGY

Control display

Power board

AL03

Excessive motor absorption

Alarm displayed when the machine is operating in Service

Mode Service Mode or Super

AL04

Temperature probe damaged

This alarm stops the operation of the machine

AL05

Circuit board transmission error

This alarm stops the operation of the machine

AL06

Unplanned motor stop

Alarm displayed when the machine is operating in Service

Mode Service Mode or Super

AL07

24V power supply missing

This alarm stops the operation of the machine

AL08

Excess current, hardware protection intervention

Alarm displayed when the machine is operating in Service

Mode Service Mode or Super

AL09

Error Hall probes

This alarm stops the operation of the machine

AL10

Lack of communication between master and slave card 1 This alarm stops the operation of the machine

AL11

Lack of communication between master and slave card 2 This alarm stops the operation of the machine

AL12

Alarm low voltage motor

This alarm don’t stops the operation of the machine

AL13

System clock out of order

System clock out of order. The machine can work but the de-

frost timer can’t be used.

AL14

Clock battery out of order

Clock battery expired or out of order. The machine can work

but current time is reset when the machine is powered off.

Version

Notes

0.22

First production version.

0.23

Updates 2013.

1.01

Updates 2014.

First produtcion version with LCD display.

1.08

Updates 2015. 

Version

Notes

0.06

First production version.

0.10

Updates 2013.

0.27

Updates 2014.

Compatible version with new LCD display.

0.35

Updates 2015.

Summary of Contents for B-cream HD 1

Page 1: ...d 16 and the power supply transformer 15 for both the circuit boards and the geared motor to drive the mixers The upper half of the dispenser contains the transparent tank 8 designed for the food prod...

Page 2: ...ned off If you press it for two seconds the dispenser switches to Cleaning mode the mixer is on but the cooling is off F Conservation indicator light flashing light product conservation mode selected...

Page 3: ...selected product ready H Ice cream production key allows you to select the ice cream production operating mode On dispensers with more than one tank if you hold this key down while the tank is in ice...

Page 4: ...torage mode PA05 parameter As well as the operating modes described in the Instruction Manual the dispenser may be started up in other modes which can be used for technical support These modes are sum...

Page 5: ...functioning correctly Master switch key H IMPORTANT On dispensers with more than one tank the operating parameters from PA01 to PA10 must be set separately for each tank NAME DESCRIPTION ADJUSTMENT IN...

Page 6: ...in more containers from the factory parameters PA11 to PA 27 are common to all the distributor and therefore can only be adjusted by the control panel on the right container NAME DESCRIPTION ADJUSTME...

Page 7: ...w to verify is the efficiency of the cooling system which can be reduced for example due to a leak of refrigerant gas In order to execute such a check a test with product 90 minutes long is required 7...

Page 8: ...is operating in Service Mode Service Mode or Super AL09 Error Hall probes This alarm stops the operation of the machine AL10 Lack of communication between master and slave card 1 This alarm stops the...

Page 9: ...r filter 2 Loosen the fastening screws and remove the side panels 3 Loosen the screws and remove the front panel Then remove the condensation water drain cover 4 Once you have removed the cover the ta...

Page 10: ...he rear of the board Loosen all the housing securing screws and then remove the board itself 3 To remove the power board you need to disconnect all the connectors then pull down the two side anchor ta...

Page 11: ...EFROSTING FAN AND THE LID PRESENCE SENSORS 1 Remove the air conveyor by pressing on either side Pull the defrosting fan out of its seat in the conveyor The lid presence detectors are situated at the r...

Page 12: ...To update the control board firmware perform the steps described below 1 Collect the programmer to the USB port on the PC where the firmware update files are stored The programmer will be recognised b...

Page 13: ...GRAMMING light will flash for a few seconds and when it remains permanently lit programming has been terminated correctly 4 Switch off the master switch and disconnect the machine from the mains 5 Dis...

Page 14: ...ure 4 Referring to figure 3 proceed as follows 1 Begin the inspection at the High Pressure zone discharge of the compressor Check around the seals 2 Follow the copper pipes to the condenser and check...

Page 15: ...illing unit on the pressure gauge to the charging unit 2 Connect the VAC filling unit to the vacuum pump and open the VAC valve 3 Open the valve on the charging unit and for a moment also open the REF...

Page 16: ...re covered with frost 9 Close the LOW valve disconnect the LOW pipe from the compressor charging pipe and screw the cap onto the bottom of the charging pipe As an indication the temperatures and corre...

Page 17: ...ply circuit board 2 Transformer 9 Display circuit board 3 Electrovalve 10 Temperature probe 4 Compressor 11 Reed safety switches 5 Fan 13 LED board hat optional 6 Geared motor 14 LED Board cop shoulde...

Page 18: ...board 2 Transformer 10 Temperature probe 3 Electrovalve 11 Reed safety switches 4 Compressor 13 LED board hat optional 5 Fan 14 LED Board cop shoulder optional 6 Geared motor 15 LED Strip cop shoulder...

Page 19: ...DIAGRAM POWER SUPPLY DISPLAY MINIGEL 17 TOPOGRAFIC DIAGRAM POWER SUPPLY DISPLAY MINIGEL PLUS KEY M1 Temperature probe M2 MASTER board M3 Faucet Reed switch opt KEY M1 Temperature probe M2 MASTER board...

Page 20: ...ost fan M4 Solenoid valve M12 Earthing M5 Compressor M13 Slave 1 board M6 Display board M14 Slave 2 board M7 Not connected M15 Closed machine without solenoid valve M8 Top cover LED board M16 Open mac...

Page 21: ...49 20 TOP COVER LED TOPOGRAPHY 21 REAR COVER LED TOPOGRAPHY KEY M1 Motherboard M2 LED strip power supply board KEY M1 LED power supply board M2 Rear cover LED strip...

Page 22: ...e density adjustment will be auto matically reduced by one unit Hold down the H key for two seconds to cle ar the alarm message The machine does not start up Message AL04 is indicated on the display T...

Page 23: ...ine to the power supply Message AL13 shown on the display System clock out of order The machine can work but the defrost timer can t be used Replace display pcb Message AL14 shown on the display Batte...

Page 24: ...otor is not functioning short circuit or mechanical blockage Replace the compressor see chapter 10 Electrovalve is not opening coil Replace electrovalve coil Electrovalve is not opening body Replace e...

Reviews: