5  PARAMETER RESET

To reset the parameters to the default values it is necessary to switch on the machine, using the main switch located under the unit,

holding down keys C and D simultaneosly, selecting YES value pressing key C and then confirming it, pressing key A.

It is also possible to reset the parameters to the default values starting the machine in Super Service Mode, selecting parameters

PA27, selecting YES value pressing key C and then confirming it, pressing key A.

6  FUNCTIONAL TEST OF THE MACHINE

The following procedure allows to test the complete functionality of the unit:

1

Switch On the machine.

2

If in Standby set the machine in Working Mode.

3

Set all  the bowls in Ice Cream Mode: the gear motors must turn regularly. The icon J  flashes on the right display. The icons I

flash  on all the displays.

4

After 15 seconds, when the time set by parameter PA15 is expired (delay timer of the solenoid valves, factory default 15 sec.)

the solenoid valves open (the sound "click" must be heard one time for each bowl in  a short time). The icon J, on all the display,

stop  flashing becoming  still.

5

After 180 seconds, when the time set by parameter PA14 is expired (delay timer of the compressor, factory default 180 sec) the

compressor and the fan motor start. Now the cooling system of the machine is working and after some ten of seconds the

evaporators must begin to freeze in the front lower part. The icon I, on the right display, stops flashing  becoming still.

6

If it is possible to complete this procedure with success it means that the machine works properly.

This test takes approx. 5 minutes and allows to verify the proper working of the gear motors, of the compressor, of the fan motor, of 
the solenoid valves and of the electronic boards all together.
The only thing that this procedure can't allow to verify is the efficiency of the cooling system which can be reduced for example due 
to a leak of refrigerant gas. In order to execute such a check, a test with product,  90 minutes long, is required.

7  PROTECTION AGAINST EXCESSIVE DENSITY

In the case of excessive product density, in order to avoid damage to the dispenser, both the freezer and the mixer will be stopped 
for three minutes and one of the following messages will appear on the display: “AL03”, “AL06” or “AL08”. After three minutes, both 
mixing and freezing will be reactivated and the previous density setting will be decreased by one level.
To reset the alarm message and return to the fixed display, hold down the B key for three seconds.
From serial number 1184, with the introduction of firmware versions 025 and 018, the alarm display has been replaced by the symbol 
---- shown on the display.
The alarm display is possible in Service Mode or Super Service (see paragraph 3 and 4) or, during normal operation, by simultane-
ously pressing the + and -.

8  ALARMS

The table below summarises the machine’s alarm codes:

PA15

Electrovalve lockout time OFF

0…600 s

20

PA16

Time for which the density must remain above the reference value

0…60 s

1

PA17

Conservation Mode Temperature Hysteresis

0…5 °C

0,5

PA18

Maximum motor absorption

YES…NO

120

PA19

Motor cooling time

0…600 s

90

PA20

Motor protection intervention delay

0…60 s

5

PA21

Product conservation alarm temperature

0…10 °C

4

PA22

Tap sensor entry activation

ON / OFF

OFF

PA23

Available for future implementations

2015 version : locking density

0...25

YES / NO

0

NO

PA24

Mixer rotation inversion when in conservation mode

YES…NO

YES

PA25

Mixer rotation inversion delay

0…3600

900

PA26

Minimum time of rotation speed increasing when cup is detected

0…60

10

PA27

Reset of the parameters to default values

YES…NO

NO

Code

Title alarm

Note

COV

Cover opened

It warns the operator that the machine can not operate if the

lid is not closed

AL02

Product temperature alarm

This alarm stops the operation of the machine

Summary of Contents for B-cream HD 1

Page 1: ...d 16 and the power supply transformer 15 for both the circuit boards and the geared motor to drive the mixers The upper half of the dispenser contains the transparent tank 8 designed for the food prod...

Page 2: ...ned off If you press it for two seconds the dispenser switches to Cleaning mode the mixer is on but the cooling is off F Conservation indicator light flashing light product conservation mode selected...

Page 3: ...selected product ready H Ice cream production key allows you to select the ice cream production operating mode On dispensers with more than one tank if you hold this key down while the tank is in ice...

Page 4: ...torage mode PA05 parameter As well as the operating modes described in the Instruction Manual the dispenser may be started up in other modes which can be used for technical support These modes are sum...

Page 5: ...functioning correctly Master switch key H IMPORTANT On dispensers with more than one tank the operating parameters from PA01 to PA10 must be set separately for each tank NAME DESCRIPTION ADJUSTMENT IN...

Page 6: ...in more containers from the factory parameters PA11 to PA 27 are common to all the distributor and therefore can only be adjusted by the control panel on the right container NAME DESCRIPTION ADJUSTME...

Page 7: ...w to verify is the efficiency of the cooling system which can be reduced for example due to a leak of refrigerant gas In order to execute such a check a test with product 90 minutes long is required 7...

Page 8: ...is operating in Service Mode Service Mode or Super AL09 Error Hall probes This alarm stops the operation of the machine AL10 Lack of communication between master and slave card 1 This alarm stops the...

Page 9: ...r filter 2 Loosen the fastening screws and remove the side panels 3 Loosen the screws and remove the front panel Then remove the condensation water drain cover 4 Once you have removed the cover the ta...

Page 10: ...he rear of the board Loosen all the housing securing screws and then remove the board itself 3 To remove the power board you need to disconnect all the connectors then pull down the two side anchor ta...

Page 11: ...EFROSTING FAN AND THE LID PRESENCE SENSORS 1 Remove the air conveyor by pressing on either side Pull the defrosting fan out of its seat in the conveyor The lid presence detectors are situated at the r...

Page 12: ...To update the control board firmware perform the steps described below 1 Collect the programmer to the USB port on the PC where the firmware update files are stored The programmer will be recognised b...

Page 13: ...GRAMMING light will flash for a few seconds and when it remains permanently lit programming has been terminated correctly 4 Switch off the master switch and disconnect the machine from the mains 5 Dis...

Page 14: ...ure 4 Referring to figure 3 proceed as follows 1 Begin the inspection at the High Pressure zone discharge of the compressor Check around the seals 2 Follow the copper pipes to the condenser and check...

Page 15: ...illing unit on the pressure gauge to the charging unit 2 Connect the VAC filling unit to the vacuum pump and open the VAC valve 3 Open the valve on the charging unit and for a moment also open the REF...

Page 16: ...re covered with frost 9 Close the LOW valve disconnect the LOW pipe from the compressor charging pipe and screw the cap onto the bottom of the charging pipe As an indication the temperatures and corre...

Page 17: ...ply circuit board 2 Transformer 9 Display circuit board 3 Electrovalve 10 Temperature probe 4 Compressor 11 Reed safety switches 5 Fan 13 LED board hat optional 6 Geared motor 14 LED Board cop shoulde...

Page 18: ...board 2 Transformer 10 Temperature probe 3 Electrovalve 11 Reed safety switches 4 Compressor 13 LED board hat optional 5 Fan 14 LED Board cop shoulder optional 6 Geared motor 15 LED Strip cop shoulder...

Page 19: ...DIAGRAM POWER SUPPLY DISPLAY MINIGEL 17 TOPOGRAFIC DIAGRAM POWER SUPPLY DISPLAY MINIGEL PLUS KEY M1 Temperature probe M2 MASTER board M3 Faucet Reed switch opt KEY M1 Temperature probe M2 MASTER board...

Page 20: ...ost fan M4 Solenoid valve M12 Earthing M5 Compressor M13 Slave 1 board M6 Display board M14 Slave 2 board M7 Not connected M15 Closed machine without solenoid valve M8 Top cover LED board M16 Open mac...

Page 21: ...49 20 TOP COVER LED TOPOGRAPHY 21 REAR COVER LED TOPOGRAPHY KEY M1 Motherboard M2 LED strip power supply board KEY M1 LED power supply board M2 Rear cover LED strip...

Page 22: ...e density adjustment will be auto matically reduced by one unit Hold down the H key for two seconds to cle ar the alarm message The machine does not start up Message AL04 is indicated on the display T...

Page 23: ...ine to the power supply Message AL13 shown on the display System clock out of order The machine can work but the defrost timer can t be used Replace display pcb Message AL14 shown on the display Batte...

Page 24: ...otor is not functioning short circuit or mechanical blockage Replace the compressor see chapter 10 Electrovalve is not opening coil Replace electrovalve coil Electrovalve is not opening body Replace e...