Description of the Unit
4-4
Digital Compact
4.3
Inputs and Outputs
The following
input signals
are provided for each module:
The following
output signals
are provided for each module:
Tab. 4-1
Input signals of the power supply module
Input Signal
Function
Ultrasonics On
Initiates release of ultrasonics.
External Reset
Resets alarm status.
Frequency seek
Starts the automatic frequency seek. The
acoustic stack is operated at low-level
(approx. 5%) for determining the resonant fre-
quency. The value determined is stored.
Amplitude control
Enables adjusting of the amplitude from
100% down to 50%.
0V - 10V corresponds to an amplitude of
50% - 100%.
Tab. 4-2
Output signals of the power supply module
Output Signal
Function
Overload
Power supply overload, or the unit was not
turned on.
Window low
Minimum power not reached or start signal
lost before end of weld cycle.
Window high
Maximum power exceeded.
Weld ON
Welding activated.