Troubleshooting
7-6
Digital Compact
When touching the
equipment you experi-
ence a slight electric
shock.
DANGER!
If none of the reme-
dial actions described
is successful, imme-
diately de-energise
the equipment!
• Inspect connecting socket and power
supply cable for damage.
• Inspect mains connection.
In this case, replace the power supply
module and send the defective one to
BRANSON Ultrasonics.
The temperature of
horn, booster and
Converter exceeds
40°C.
Occasional occur-
rence of overload con-
ditions.
• Check for fretting corrosion on the
mating surfaces of the acoustic stack.
Fretting corrosion results in a black,
crusty build-up resulting from friction
between metal parts.
Remove this deposit (please refer to
chapter 7.2.5).
Tab. 7-5
Troubleshooting: Weld cycle
Fault
Cause and Remedy
STOP