against  sub-standard  manufacturing  workmanship  and 
faulty components for a period not exceeding

 3 years

 from 

the date of purchase.

8

VALIDITY of  WARRANTY OFFER :-

The  validity  of  the  warranty  is  conditional  upon  the 
ownership  of  the  door  operator  being  registered  with 

Brano

.

Doors such as Sectional type and Spring-Pantograph Tip-
Up type doors qualify for coverage under this warranty. In 
every instance the installation of the door operator shall be 

strictly in accordance with the prescribed installation 
instructions.

A period of

 60, ( sixty ), days

 

from the date of p

u

rchase / 

installation  of  the  garage  door  operator

 

shall  be 

allowed  for  the  purpose  of  registering  o

w

nership. 

Proof of date of purchase is required.

9

REGISTRATION CARD:-
The attached registration card is to be filled ou

t

 and 

returned  to 

Brano.

 

Be  sure  to  record  all  the

 

information requested:-

9.1 The operator's 

serial number.

9.2 The 

date of installation.

9.3 If  applicable,  the  type  of  door  adaptor  kit  installed,  e.g. 

"Pro-Rola 1"

 

system or "Side-mount" 

s

ystem.

9.4 The 

Type

 

of  garage  door  you  own  and  the  date  t

h

door was purchased.

9.5 The 

Name 

o

f your Dealer / Installer.

10 ACCEPTANCE OF EXTENDED WARRANTY:-

No extended warranty shall be deemed to exist unless all 
the information stipulated is supplied.

11

CORRESPONDENCE:-

Always  state  the  operator's  Serial  Number  in  any 
correspondence relating to warranty claims.

12 WARRANTED  COMPONENTS:-

12.1

Brano 

warrants that all mechanical and  e l e c t r i c a l  

components  of  the

  'pro-alpha  2000" 

garage  door 

operator

 

 which are supplied as part of the bas

i

c kit 

are  free  of  defect  with  respect  to  the  qual

i

ty  of  the 

materials and components used as well a

s

 the quality 

of the manufacturing and assembly wo

r

kmanship

Components include the:-

Electric  motor,  "worm-screw",  aluminium  housing,  P.C. 
control card,  attachment brackets and towing arms.

12.2

Important Note:-

The  Traveller  Assembly  and  motor-shaft  coupling  are 
designed to be 

"sacrificial" wearing parts

 

and w

i

ll not be 

considered as faulty components. They a

r

e therefore not 

covered by this warranty. 

They  are  designed  to 

"fail  first" 

i

n  order  to  prot

e

ct  more 

expensive and "difficult-to-replace" comp

o

nents. If one of 

these components fails, it is a 

s

ure sign that there is a fault 

somewhere in the s

y

stem. Most likely the garage door is 

out of balan

c

e or some component of the door system is 

malfunc

t

ioning or is damaged and requires attention.

13

EXCLUSIONS:-

The following components, services and work are 

specifically 

excluded

 

from  the 

Scope  of  this  Warranty,

 

whether 

specifically stated or implied. 

This Warranty is invalid for 

the  repair  or  replacement  of  Door  Operating  Equipment 
and Components which are :-

13.1

not supplied by

 Brano.

13

EXCLUSIONS:-

13.2

damaged by an act of

 G_D,

 

( e.g. lightning s

t

rike, 

flood, fire, power surge, etc., etc.)

13.3

damaged due to misuse or abuse of the equipment, 

as when installing the operator on doors which are not 
suited to conversion to automatic operation, (e.g. 

"Tip-

In"

 

doors or "Vertical Track"

 

type

 

doors which have 

not  been  fitted  with  an  approved

 

type  of  Door 

Adaptor Kit ).

13.4

used  for  purposes  other  than  that  for  which  it  has 

been designed, ( e.g. for the automation of driveway 
gates ). The 

"pro-alpha 2000"

 

door opera

t

or is 

not designed to operate in areas where it w

i

ll 

be exposed to the elements.

 

........ It is not  weatherproof !!!

13.5

used to operate doors which are not in good working 

order, ( e.g. doors which are improperly balanced or are 
in a state of disrepair ).

14.6

installed on doors which have to cater for very high 

traffic flows, ( i.e. more than 

10 

c

ycles

 

per day ). 

The 

equipment is designed for, and intended to be used 
in, a domestic environment .

13.7

damaged due to malicious causes or sabotage.

13.8

damaged  due  to  faulty  or  incorrect  installation 

techniques  and  substandard  workmanship,  (e.g.  non 
standard or improper wiring work, incorrect fitting of the 
operator and / or door adaptor and conversion kits ).

13.9

damaged  or  have  their  settings  disturbed  due  to 

tampering  with  the  equipment  by 

unqualified 

persons.

13.10 damaged  due  to  fair  wear  and  tear  which  is  not 

attributable  to  the  fault  of  the  company,  (  e.g. 
replacement of batteries and light bulbs, traveller nuts, 
and other 

"sacrificial" wearing parts 

)

.

14 MAINTENANCE OF THE GARAGE DOOR.

It  is,  furthermore,  a  condition  of  this  warranty  that  the 
garage  door  itself  be  maintained  in  a  serviceable 
condition  in  accordance  with  the  door  manufacturer's 
instructions and as specified in the relevant sections of 
this 

"Owner's  Operating  Manual"  and  SABS  -  IEC 

60335 - 2.

Proof of service to the doors may be required.

15 DEFECTIVE PARTS:-

Faulty components shall be repaired or replaced at the sole 
discretion  of 

Brano.

     

Defective  parts  replaced  shall 

become the property of

 

Brano.

 

16 COSTS  INCURRED  FOR  SERVICE  LABOUR, 

TRANSPORT / POSTAGE and TRAVELLING:-

Brano

 

will  be  liable  for  the  cost  of  the  replacement 

parts only !

 

That is, the cost of specialised l

a

bour and 

the cost of travelling to and from site and the cost of 
transport  or  postage  of  spare  part

s

  are  specifically 

excluded

 

from  the  scope  of  this

 

warranty.  The  faulty 

component or door operator m

u

st be returned either to

 

Brano 

or to one of its authorised Distributors for repair 

or replacement. The cost incurred for such returns shall 
be for the account of the owner or installer.

17

CANCELLATION  of  WARRANTY.

In the event of any of these conditions being breached, 

Brano

 reserves the right to cancel the warranty with 

immediate effect.

Revised :-  October 2001

Summary of Contents for pro-alpha 2000

Page 1: ...B A C O M A E S O O O E S D G N T N U E M R N A G I O B Y B A O 1 LD U E C N L O U R R R N ST O L L 2 W P E P R E R E U S G AT T L O I B R L AV M O A E 8 brano industries pty ltd p o box 277 bramley...

Page 2: ...ealers installers is simply this Fix the door before you automate it It s worthwhile doing besides it s good for business SABS IEC Standard No 60335 2 95 This standard specification is now published a...

Page 3: ...rano cape pty ltd Unit 3 EXPO Centre Koeberg Rd Deliveries 35 Stella Road Montague Gardens Cape Town Tel 021 552 5350 Fax 021 552 5350 Pretoria brano pretoria pty ltd Unit 8 Block B Scientia Techno Pa...

Page 4: ...ecial adaptor kits in order to be automated Consult your dealer for advice Refer to the specific instructions for the type of door you wish to automate 1 2 Inspection Of The Door Inspect the garage do...

Page 5: ...s and repair or replace as necessary Test the operation of the door to make sure that it is properly balanced Pay particular attention to the springs Domestic garage door springs should be replaced af...

Page 6: ...oor is fully open the entire door remains completely inside of the garage These doors were intended for use in openings that have rounded or arched shapes and were sold as a cheaper alternative to Sec...

Page 7: ...r in the way shown above the built in overload sensors of the door operator regardless of make and type may be severly compromised to the extent that they may not respond quickly enough if at all to a...

Page 8: ...LUBRICANT GDO L1 OR LOW TEMP LUBRIPLATE OR AVGREASE 28 Serial Number 299 A 8 3478 GENERALDESCRIPTION Electrically operated automatic garage door operator for use on domestic type garage doors MAINFRAM...

Page 9: ...or the garage itself does not conform to standard specifications special equipment may be required Contact your nearest agent dealer for advice The following items are not included in the standard ope...

Page 10: ...ages Without Secondary Access Doors If there is no other means of access into the garage except through the main garage doors themselves it is necessary to install an Emergency Key release Kit for the...

Page 11: ...Highrise Level Required Headroom Lintel Ceiling High Rise Point of Door pro alpha 2000 Path of Topmost Section of the Door 1 2 3 Floor to top of door operator 5 6 7 4 Opening No of Track Headroom High...

Page 12: ...ncluded for installation purposes Refer to the relevant sections of this manual Minimum Clearance Required From Door High rise Point to Ceiling 75 mm Sectional Doors Operator to Door Clearance at high...

Page 13: ...ition the Header Anchor Bracket on the wall in such a way that the right angle face of the bracket coincides with the centre line mark of the door 4 3 7 Mark the positions for the fixing screws and dr...

Page 14: ...on the operator on the centreline of the door Preferred Arrangement Not Recommended 4 5 1 Mounting the Power head 4 5 2 Establish the position of the nearest roof beams or other suitable overhead stru...

Page 15: ...4 8 1 Use both the L Shaped Towing Arm and the Straight Towing Arm to couple the door to the traveller as shown in Fig 27 The L Arm is attached to the door whilst the Straight Arm is connected to the...

Page 16: ...hrise Point to Ceiling Floor Level Height of Door Opening Standard 2135 mm Floor to High rise Point 2310 mm for std height door Top of Door closed Underside of Door Operator Floor to Top of Wall Anch...

Page 17: ...r as possible 5 2 2 Use the three 12 x 28 mm hex head Lag Screws provided to fix the Door Bracket to the door 5 5 Alternative Towing Arm Arrangement for TIP Up Door Door Towing Bracket L Shaped Towing...

Page 18: ...t to the ceiling and make use of an Extended Towing Arm to couple the door to the operator p o r 0 0 a 0 h p a l 2 SECTION 5 PROBLEM INSTALLATIONS i n d u s t r i e s Fig No 34 H i g h r i s e P o i n...

Page 19: ...is fitted to a door when the only access into the garage is through the garage doors themselves i e there is no back or side door entrance into the garage This special release mechanism permits the ma...

Page 20: ...itivity Terminal Block for connection of Radio Receiver Wall Pushbutton and Safety Beams pro alpha 2000 PC BOARD GENERAL LAY OUT brano industries pty ltd PC Board Lay out FORCE ADJUSTMENT CLOSING OPEN...

Page 21: ...e directly on the PC Board of the pro alpha 2000 door operator to install various types of safety beams and pressure sensors Refer to the relevant manufacturers instructions for connecting information...

Page 22: ...operator s PC Board SAFETY BEAM Operator PC Board Note PC Board jumper switch is set to BEAM position These connection diagrams are intended to serve as a guide only Always refer to the instructions s...

Page 23: ...TCH SETTINGS All types of doors 7 1 UP Limit Switch 7 1 1 First Open and close the door manually to ensure that it does not foul any part of the operator 7 1 2 Second Manually open the door to the ful...

Page 24: ...or can gain when it is wet The operator should be set to pull and push with a force of between 5 10 Kg Regardless of the size of the door 7 5 The Safety Overload Feature will be automatically activate...

Page 25: ...disengaged i e the door is not coupled to the operator 8 1 1 Switch the power supply ON 8 1 2 Check that the Red Power On indicator l i g h t situated under the PC Board is illuminated 8 1 3 Using eit...

Page 26: ...minent positions close to the garage door and door operator where they may be seen and read by all users of the equipment It is the responsibility of the installer to ensure that this is done Failure...

Page 27: ...me damaged if the door has suffered an impact with a car or has been forced open Whatever the cause the entire system needs to be carefully inspected The reasons for making these 2 components sacrific...

Page 28: ...Cable Push button Emergency Release Pull Cord Door Towing Bracket Door Header Anchor Bracket Traveller Assembly 2 EPK 2 TOWT 1 AP 20 LAB 02 LAB 04 4 FK PA MAN 01 MAN 02 2 TOWLS 2 TOWSS 4 FPC 1028 2 E...

Page 29: ...Model DO 10 Note Not interchangeable with pro alpha Series 1 PC Boards 2 PCB 2 Important Note The Worm shaft and Aluminium Extrusion are sold as a matched pair only Electric Motor Motor Capacitor Bas...

Page 30: ...Board for damage e g from a lightning strike power surge etc 3 2 The Worm Shaft may be jammed or seized due to the ingress of dirt or some other foreign matter Clean out the Aluminium Extrusion with...

Page 31: ...rator works from the Wall Push button but not from the remote Transmitter SOLUTIONS 8 TROUBLE SHOOTING GUIDE Section 10 continued SYMPTOM 9 Operator works from the Transmitter but not from the Wall Pu...

Page 32: ...6 5 The PC Control Board may be faulty SYMPTOM 16 SOLUTIONS 16 The operating range of the Remote Radio Transmitter is very short SYMPTOM 17 17 1 Replace the Battery in the Transmitter 17 2 The Radio T...

Page 33: ...1 Check that the Travel Limit Switch Wires are properly inserted into the Limit Switch Terminals 20 2 The Travel Limit Switch Brackets may be loose and have moved Set them in the correct position and...

Page 34: ...2000 garage door operator will then be covered brano door operator installation manual page 32 1 DEFINITIONS In these terms and conditions 1 1 Brano shall mean Brano Industries Pty Ltd or it s subsid...

Page 35: ...of Door Operating Equipment and Components which are 13 1 not supplied by Brano 13 EXCLUSIONS 13 2 damaged by an act of G_D e g lightning strike flood fire power surge etc etc 13 3 damaged due to misu...

Page 36: ...Up Steel Roll Up Door Size Width mm Height mm Mass kg Adaptor Kit Used Not Applicable Pro Rola 1 Pro Rola 2 Low Headroom Ki Other Remote Controls Make and Model Receiver Type Single Channel Multi Chan...

Reviews: