3.3.4 Serial Port Link Configurations
To configure the links, remove the back cover of the unit, locate the links, and configure them using
the Link Location Drawing and Link Configuration Table.
Link Location Drawing
Link Configuration Table
LINK SETTING
DESCRIPTION
JP1 1 - 3
RS422
JP1 6 - 8
RS422 transmit data
JP1 8 - 10
RS422 receive data
JP1 3 - 5
RS232
Please note that two links need to be set for RS422 configuration. To receive only, set link 1-3 and
link 8-10. To receive and transmit, set link 1-3 and link 6-8.