59
MANUAL P/N 900000111 REV K
PhaseErr
OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Phase Error"
::= { status 7 }
8.4.8
DACVOLT
Description
DACVOLT
Type
MIB Read
1.3.6.1.4.1.18954.5.3.8.0
String
MIB Write
DAC voltage (0-5V).
DACVOLT
OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "DAC Volt (0-5V)"
::= { status 8 }
8.4.9
Output Status
Description
OutputStatus
Type
MIB Read
1.3.6.1.4.1.18954.5.3.9.0
Integer
MIB Write
FaultStatus
OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Output Status"
::= { status 9 }
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PPS11 PPS10 PPS9 PPS8 PPS7 PPS6 PPS5 PPS4 PPS3 PPS2 PPS1 I_DC IRIG HQ2 HQ1
PPS[11..1]
1 = PPS[11..1] output fault
I_DC
1 = IRIG DC output fault
IRIG
1 = Modulated IRIG output fault
HQ[2..1]
1 = HaveQuick output[n] fault