3
Diagram C
Overall dimension
description
If clearance between side
and
rear
walls
and
periphery of the burner is
less than 150mm, the wall
must be protected with a
non-combustible material.
The protection must extend
a minimum distance of
450mm above the burner.
Horizontal surfaces less
than 730mm vertically
above the Domino must
also be protected.
Keep all natural air-vents open or have a mechanical ventilation system installed (a
mechanically ventilated hood).
- Prolonged, intensive use of the hob may require extra ventilation; by opening a window for
example or producing more efficient ventilation by increasing the power of the existing
mechanical ventilation (a minimum air input 2m3/hr per kW of gas energy is required)
For example: 5.0kW (total power) X 2 = 10 m3/h minimum flow rate required
3.
Install the Domino in the cut-out (See diagram B).
4.
The gas connection to the external gas governor is 1/2”BSP. Please ensure
sealing gasket/washer is in place while connecting to gas supply pipe.