SERVICING INSTRUCTIONS 

(For registered gas installer only!) 

MINOR ADJUSTMENTS 

 

 

Access to By Pass Screw 

 

 

Access to manifold, gas taps and burner 
assembly 

-

 

Light  the  burner  and  turn  to  minimum 
setting (marked small flame). 

-

 

The flame should be stable on minimum 
setting  and  should  not  extinguish  when 
passing  from  maximum  setting  to  low 
setting. 

-

 

If  adjustment  is  necessary,  remove  the 
control  knob  by  pulling  upward.    The 
bypass  screw  is  accessible  via  the 
control  knob  spindle.    Turn  the  bypass 
screw  anti-clockwise  to  increase  the 
turndown rate.

 

 

-

 

Remove glass hob and control knobs.

 

-

 

To  remove  gas  cocks.    Unscrew  the 
locking  nut  (between  cock  and 
burner).  Remove screws, the cock can 
now be removed from the manifold.  If 
access to the barrel is required, remove 
two  screws,  which  retain  spindle  to 
body.    If  lubricating  the  mechanism 
use  Regosine  Moly  LM  or  other 
approved grease.

  

 

 

 

FAULT ISOLATION CHART (For registered gas installer only!) 

FAULT 

CAUSES 

REMEDY 

Burner will not light 

1.

 

Air in gas line 

2.

 

Blockage in line  

3.

 

Ignition not sparking 

4.

 

Flame failure device faulty 

5.

 

Check the battery 

(applicable 

to DC version)

 

1.

 

Purge gas line  

2.

 

Trace back and clear 

3.

 

Check lead and electrode 

4.

 

Replace thermocouple and test 

5.

 

Replace the battery 

Burner lights back to 
injector 

1.

 

Excessive lint up of burner 
mixing tube 

2.

 

Excessive gas pressure 

1.

 

Remove and clean burner 

2.

 

Check gas pressure.  

Burner has explosive 
ignition 

1.

 

Excessive gas pressure 

1.

 

Check gas pressure. 

Igniter not sparking 

1.

 

Electrode gap  

 
2.

 

Igniter connections 

1.

 

Check gap, adjust if not 
between 4-5mm 

2.

 

Check connections to igniter, 
replace if faulty. 

In case you have any problem or enquiry, please contact the after service team of the 

Summary of Contents for TG1089XC

Page 1: ...lations AGA Installation Code for Gas Burning Appliances and Equipment and any codes and regulations These instructions should be read carefully prior to initial use and retained in a safe place in or...

Page 2: ...nnected in the position shown in Diagram A Diagram A Diagram B Tray Dimensions unit in mm Cut out unit in mm 2 Cut the opening in the bench top to the dimensions shown in diagram B The hob must be bui...

Page 3: ...cal ventilation system installed a mechanically ventilated hood Prolonged intensive use of the hob may require extra ventilation by opening a window for example or producing more efficient ventilation...

Page 4: ...the gas leakage 8 Room Ventilation When installing built in gas hob on top of stove cabinet please check that there is provision for ventilation at the cabinet to ensure proper operation of the gas ho...

Page 5: ...the FULL ON position 2 When the burner has ignited adjust the control knob to the required setting Flame adjustment is achieved by rotating the control knob further in an anti clockwise fashion toward...

Page 6: ...INO Utensils should always be placed centrally on the pan supports and over the burners Flames which extend beyond the bottom of utensils are wasteful and can damage or overheat handles Large diameter...

Page 7: ...not obstructed In the event that you are not satisfied with the Domino the distributor in your region should be consulted IMPORTANT ANY SERVICING TO THIS APPLIANCE MUST BE CARRIED OUT BY A REGISTERED...

Page 8: ...e burner The appliance shall not be used as a space heater The panel of this built in hob is made of tempered glass which is safer than normal glass for this application However the following safety p...

Page 9: ...emove two screws which retain spindle to body If lubricating the mechanism use Regosine Moly LM or other approved grease FAULT ISOLATION CHART For registered gas installer only FAULT CAUSES REMEDY Bur...

Page 10: ...1 Gas type TG Nominal heat rating kW 5 Injector diameter mm 3 3 Safety cut off yes Working pressure kPa 1 Gas inlet connection inch screw 1 2 BSP Tray depth mm 45 Clearance from base tray of domino t...

Page 11: ...11...

Page 12: ...12 1 TG1089XC A English B B...

Page 13: ...13 1 A A B 2 2 2 2 B B 3 C 30 10 15...

Page 14: ...14 C 150 450 730 2 5 0kW X 2 10 m3 h 3 3 3 3 B 4 4 4 4...

Page 15: ...15 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 EMSD APPROVAL GTXXXX Beckley 2300 1kPa...

Page 16: ...16 TG1089XC TG1089XC FULL ON 1 FULL ON 2 3 1 2 3 1 5 D 4...

Page 17: ...17 200...

Page 18: ...18 1 5...

Page 19: ...19 50 1 2 3 4...

Page 20: ...20...

Page 21: ...21 1 2 3 4 5 1 2 3 4 5 1 2 1 2 1 1 1 2 1 4 5 2...

Page 22: ...22 TG1089XC DC 1 5 6 1 5 3 3 1 1 2 45 53 x 472x 260 x 510 x 300 x 477x 265 7 6 Beckley Beckley 2300 1...

Reviews: