8
These instructions are intended to be used by a qualified
installationist, who will be responsible for the installation,
adjustment and maintenance according to the laws and
regulations in force.
All operations must always be carried out with the
equipment disconnected from the electricity.
Instructions for the installationist
Installation
Positioning
Electric connections
(Fig. 2) The apparatus is designed to be set into a work
surface, as shown in the relevant illustration.
Fit the seal provided round the whole perimeter of the
surface.
Before connecting up the electricity, ensure that:
- the specification of the system is such as to match that
shown on the serial number plate applied to the under-
neath of the work surface.
- the system is supplied with an efficient earth con-
nection to the ground, according to the regulations and
the laws in force. The earth connection is obligatory by
law.
In the case where the equipment is not supplied with
cable and/or relevant plug, make use of materials suited
to the input current shown on the serial number plate,
and to the working temperature. The cable must not
reach a temperature of more than 50°C higher than the
ambient temperature in any part of its length.
In order to connect directly to the mains supply, it is
necessary to insert a multipolar switch with a minimum
aperture between contacts of 3 mm, of a size suitable
for the load marked on the plate, and conforming to the
regulations in force (the yellow and green earth cable
must not be turned off by the switch). The plug or multi-
polar switch must be easily reached with the equipment
installed in position.
N.B.: The manufacturer declines any responsibility in the
case where the above and the normal accident prevention
regulations have not been respected.