ENGLISH
52 / 78
CAP. 11 - REFRIGERANT FLUID CIRCUIT
MULTIGAS 8500
11.2
OPERATIONAL CYCLES
The equipment enables, with a single series of operations, to recover and recycle the refrigerant
fluids without dispersions in the environment, also removing humidity and various deposits
contained in the oil from the A/C system. In fact, inside the equipment there is an
evaporator/separator through which oil and other impurities are removed from the refrigerant
fluid recovered from the A/C system, then collected in a suitable container. The fluid is then
filtered and re-injected, perfectly recycled, inside the tank in the equipment. Through the
equipment it is also possible to carry out some A/C system functioning and capacity tests.