ENGLISH
22 / 78
CAP. 6 - MAINTENANCE
MULTIGAS 8500
6.4
WEAR CHECK OF THE RED AND BLUE CHARGE HOSES AND
THE HP RED AND LP BLUE QUICK COUPLERS
Check that the entire length of the piping does not present:
•
abrasions, cracks, cuts, irreversible folds, deformations, twists.
Check that the contact points between the piping and the joints with quick couplers and with the
equipment do not present:
•
abrasions, cracks, cuts, irreversible folds, deformations, twists.
Check that the quick couplers do not present:
•
abrasions, excessive plays, cracks, deformations.
TESTS of the piping and quick couplers tightness with leak tests under vacuum and under pressure
conditions.
•
Connect the hoses through quick couplers to the false joints on the wall of MULTIGAS 8500
and open the taps/valves;
•
Launch the “Leak test” function inside the Maintenance Menu, check that the test is passed
successfully.
•
From the Service menu - “Manual activation”, activate valves “R” and “I”, check that the
hoses are pressurized (at least 5 bar) and check that the pressure does not drop in a time
slot equal to 30 minutes and that gas leaks do not occur.
In case the station is equipped with the ECO LOCK® quick couplers, you shall check that the ECO
LOCK® function is enabled within the “SETTINGS” menu – “ECO LOCK” submenu.
In case the previous couplers are replaced with the ECO LOCK® quick couplers, you shall enable
the ECO LOCK® function within the “SETTINGS” menu – “ECO LOCK” submenu.
6.4.1
ECO LOCK® QUICK COUPLERS
ECO LOCK® is the INTELLIGENT COUPLER, Brain Bee patented, that with the suitable automated
procedure in the software enables to:
1.
reduce the formation of non condensable gas inside the vessel ;
2.
avoid refrigerant dispersion in the air during disconnection ( puff effect);
3.
check possible SCHRADER valve leaks before disconnection.
The ECO LOCK® quick couplers accomplish ground-breaking functions, for which they are
conceived, only if the ECO LOCK® function is enabled within the “SETTINGS” menu – “ECO
LOCK” submenu of the specific equipment.
Summary of Contents for multigas 8500
Page 11: ...ENGLISH 11 78 CAP 5 INSTALLATION MULTIGAS 8500...
Page 46: ...ENGLISH 46 78 CAP 9 UPDATE MULTIGAS 8500 Select update device...
Page 53: ...ENGLISH 53 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 RECOVERY...
Page 54: ...ENGLISH 54 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 VACUUM...
Page 55: ...ENGLISH 55 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 OIL TRACER INJECTION...
Page 56: ...ENGLISH 56 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 RECHARGE...
Page 57: ...ENGLISH 57 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 NON CONDENSABLE GASES DISCHARGE...
Page 66: ...ENGLISH 66 78 CAP 14 SPARE PARTS MULTIGAS 8500...