ENGLISH
31 / 78
CAP. 7 - CALIBRATION
MULTIGAS 8500
7.3
PRESSURE CALIBRATION (SERVICE KIT)
From the SERVICE menu, password “BRN”, select the PRESSURE CALIBRATION menu by means
of the keys
and press
.
Disconnect the LP and HP quick couplers from any A/C system and press
.
Wait for the message asking to connect the tank coupler, included in the clima station accessories
kit; when the next message is displayed, screw HP so that air gets into the HP hose.
Turn the HP quick coupler clockwise to open it and press
Wait for the message to connect the reference gauge contained in the service kit.
Close the HP quick coupler by rotating it counter clockwise and connect it to the gauge present in
the SERVICE KIT, open the HP quick coupler by rotating it clockwise and press
.
SAFETY NOTE:
ATTENTION NOT TO POINT THE GAUGE TOWARDS ONESELF OR OTHER PEOPLE UNTIL ONE
HAS THE ABSOLUTE CERTAINTY THAT THE CONNECTION WITH THE QUICK COUPLER IS
SAFE.
OPEN THE TAP OF THE QUICK COUPLER BY POINTING THE GAUGE TOWARDS THE
GROUND, ALWAYS KEEP THE GAUGE TOWARDS THE GROUND EXCEPT WHEN THE GUIDED
PROCEDURE REQUIRES ENTERING THE VALUE DISPLAYED ON THE SAMPLE GAUGE.
Measure the pressure reached by the SERVICE KIT gauge and, by means of the keys
, set
it on the Unit and press
.
Subsequently the equipment will execute the vacuum, at the end of which one will be asked to
check that the gauge reaches -1 bar, when requested by the guided procedure press
to
confirm calibration.
Summary of Contents for multigas 8500
Page 11: ...ENGLISH 11 78 CAP 5 INSTALLATION MULTIGAS 8500...
Page 46: ...ENGLISH 46 78 CAP 9 UPDATE MULTIGAS 8500 Select update device...
Page 53: ...ENGLISH 53 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 RECOVERY...
Page 54: ...ENGLISH 54 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 VACUUM...
Page 55: ...ENGLISH 55 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 OIL TRACER INJECTION...
Page 56: ...ENGLISH 56 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 RECHARGE...
Page 57: ...ENGLISH 57 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 NON CONDENSABLE GASES DISCHARGE...
Page 66: ...ENGLISH 66 78 CAP 14 SPARE PARTS MULTIGAS 8500...