ENGLISH
19 / 78
CAP. 6 - MAINTENANCE
MULTIGAS 8500
Place a container under the pump oil drain hole. Open the upper plug and then the lower
plug to drain the exhausted oil contained within the vacuum pump.
Once the pump is emptied, rescrew the bottom plug.
Fill the pump with new oil via the filler cap; use a funnel if necessary. Bring new oil level
halfway through the sight glass.
Once the pump is filled, close the top plug.
Once oil has been replaced, switch on the unit and from the MAINTENANCE menu select
PUMP OIL REPLACEMENT: press the “RESET” key to set the counter to zero.
6.2.1
Vacuum pump oil specifications
Performance and good operation of the vacuum pumps largely depend on the type of oil
being used.
Oil ensures lubrication of mechanical moving parts, tightness and vacuum level, as well as
low noise levels.
Unsuitable oil may jeopardize the pump performance, or it may cause breaking of inner
mechanisms.
For this reason, using oil provided by Brain Bee, or a type of oil having the characteristics
indicated below, is of the utmost importance.
SIGHT GLASS
UPPER PLUG
LOWER PLUG
Summary of Contents for multigas 8500
Page 11: ...ENGLISH 11 78 CAP 5 INSTALLATION MULTIGAS 8500...
Page 46: ...ENGLISH 46 78 CAP 9 UPDATE MULTIGAS 8500 Select update device...
Page 53: ...ENGLISH 53 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 RECOVERY...
Page 54: ...ENGLISH 54 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 VACUUM...
Page 55: ...ENGLISH 55 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 OIL TRACER INJECTION...
Page 56: ...ENGLISH 56 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 RECHARGE...
Page 57: ...ENGLISH 57 78 CAP 11 REFRIGERANT FLUID CIRCUIT MULTIGAS 8500 NON CONDENSABLE GASES DISCHARGE...
Page 66: ...ENGLISH 66 78 CAP 14 SPARE PARTS MULTIGAS 8500...