WBD1
Installation
16
10/29/2020
Bradley
• 215-1890 Rev. E: ECO 20-08-028A
Soap Installation
5
The soap system is designed to be used with a standard U.S.
gallon soap container. For accurate low soap indication, user
needs to set soap type (see Configuration Mode on page 20
to set soap type).
Attach soap supply tube from the
WashBar to the top of the soap pump.
A
To manually prime the soap, press
down on the control box lever arm 6 to
8 times.
F
Use the provided cable tie hook and
loop strap to secure container to soap
bracket. Feed end of cable tie (smooth
side facing you) through the right side
slot of bracket flange at top. Feed
through left side flange slot and wrap
around jug. Secure with the hook and
loop end.
D
Ensure that the soap tube is not
kinked. Position hand above soap
motor control box and adjust tube if
needed.
E
Slide gallon soap container over soap
syphon tube and into soap pump.
Set gallon soap container onto lower
soap tank bracket and hold in place.
B
C
For ease of soap container removal,
swing it away from the wall to clear the
soap container bracket and lower it to
clear the soap syphon tube.
Ensure soap pump flange
is positioned below
control box lever.
Attach soap supply tube from
WashBar here.
Top Flange
Cable Tie Slot
Soap Container
Bracket
Cable Tie Hook
and Loop Strap
Soap Pump
Soap Syphon
Tube
Soap cycle count defaults to liquid soap configuration. If you
have the foam soap option, please see Setting the Soap Type
under Configuration Mode on page 20.
The liquid soap pump has a rubber
sleeve that fits over the soap
container opening. The foam soap
pump has an interior white cylinder
that fits into the soap container. The
fit may be tight. Move the soap pump
laterally while applying pressure to
seat into soap container opening.
Small hook and loop strap