![Bradley Terreon Quadra-Fount MF2944/BIR3 Installation Manual Download Page 7](http://html1.mh-extra.com/html/bradley/terreon-quadra-fount-mf2944-bir3/terreon-quadra-fount-mf2944-bir3_installation-manual_2800368007.webp)
Installation
MF2944/BIR3
Bradley •
2215-1373 Rev. P; ECN 14-00-006 6/6/2014 7
5
Assemble and Install Bowl
Do not leave the bowl on the pedestal unsupported, as it
may fall and cause personal injury or damage to property.
Discard rubber gasket included with drain spud. It cannot be
used in this application.
A
Install two 3/8" wall anchors (supplied by installer)
which will be used to mount the bowl to wall (see
rough-ins on page 4) .
B
Carefully remove the sprayhead cover .
D
Install the two wall anchor brackets to the back of
the bowl using the 3/8"- 16 x 1-1/2" hex-head bolts,
13/32" I .D . plain washers, anchor plates, 3/8" I .D .
lockwashers, and 3/8"- 16 hex nuts provided .
F
Slide the bowl back to the wall and secure the bowl’s
wall brackets to the wall anchors with two 3/8" bolts
and washers (supplied by installer) .
G
Fasten the bowl to the upper bracket on the pedestal
assembly with the two 1/4"- 20 x 1/2" round-head
screws and 5/16" I .D . washers supplied .
H
Install the drain spud in the bowl using plumber’s
putty .
I
From beneath bowl, thread the spud washer and
spud locknut onto the drain spud and tighten the
locknut against the bowl .
J
Install strainer in the bowl drain using the two #10-24
x 1/2" flat socket head screws supplied .
K
Connect the drain trap (supplied by installer) to the
drain spud and drain line .
C
Carefully lift the bowl onto the pedestal frame using
appropriate lifting procedures . Ensure bowl remains
3-4” from the wall .
E
Uncoil the infrared sensor leads and plastic tubing
from the rear of the backsplash .
Back View of Washfountain Bowl
#10-24 x ½"
Screws for Strainer
Drain Assembly
Dome Strainer
Drain Spud
Washfountain Bowl
Discard this washer;
it is not used on
washfountains
Spud Locknut
Spud Washer