Pre-Installation Information

Terreon material

The Quadra-Fount is constructed of Terreon, a densified solid surface material composed of polyester resin . Terreon is 
resistant to chemicals, stains, burns and impact . Surface damage can be easily repaired with everyday cleaners or fine-grit 
abrasives . Terreon is NAHB certified to meet ANSI Z124 .3, Z124 .6 and ANSI/ICPA SS-1-2001 .

Infrared sensor and 6V DC solenoid valve

Each sprayhead is controlled by a 6V DC solenoid valve, allowing each user to activate a single flow of water . Each valve 
uses less than half the maximum amount of hot water allowed by the ANSI/ASHRAE/IES 90A-1980 Standard .

Barrier-free and ADA compliant

The Terreon Quadra-Fount with infrared is designed to comply with all ADA and TAS guidelines on reaches, clearances and 
operation 

when mounted at standard height dimensions by the installer

 .

Supplies Required by Installer

• 

(6) 3/8" diameter bolts with washers and (6) wall anchors appropriate for your installation

• 

(2) 3/8" diameter bolts with washers and (2) floor anchors appropriate for your installation

• 

1/2" nominal copper tubing for hot and cold water supply lines

• 

1-1/2" NPT drain trap and waste connection

• 

Pipe sealant and plumber’s putty

Summary of Contents for Terreon Quadra-Fount MF2944/BIR3

Page 1: ...reater than 80 psi Make sure that all water supply lines have been flushed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction Hardware...

Page 2: ...valve allowing each user to activate a single flow of water Each valve uses less than half the maximum amount of hot water allowed by the ANSI ASHRAE IES 90A 1980 Standard Barrier free and ADA complia...

Page 3: ...S45 2731 optional Stop Hose Valve Assembly with Two Mounting Screws MOUNTING PANELS LOWER BRACKET Parts included with the Quarda Fount Separate all parts from packaging materials and ensure you have a...

Page 4: ...6 OBC 3 1 8 79 JUV 9 1 2 241 STD 8 1 2 216 OBC 5 1 2 140 JUV 5 127 Finished Floor 1 2 Nominal Copper Tubing For Supplies Stub Out Min 1 1 2 from Wall 7 1 2 191 19 1 2 495 1 1 2 NPT Waste Connection Fo...

Page 5: ...ssembly to the wall using appropriate lifting procedures and align the locating notches on the mounting panel with the centerline marked on the wall If the floor is not level install shims under the l...

Page 6: ...s on the side of the left pedestal panel Do not thread the screw completely into the panel but allow 5 16 of the screw to be exposed D Connect the other end of each supply hose to the Navigator TMV va...

Page 7: ...two 3 8 bolts and washers supplied by installer G Fasten the bowl to the upper bracket on the pedestal assembly with the two 1 4 20 x 1 2 round head screws and 5 16 I D washers supplied H Install the...

Page 8: ...right center station to the circuit board attached to the solenoid with the black supply tube D Connect the sensor cable from the left center hand station to the circuit board attached to the solenoid...

Page 9: ...Water in excess of 110 F 43 C may cause scalding H C D Loosen Cap Screw about 4 6 turns and lift up cover do not remove E Using cover turn cartridge gently until desired water temperature is reached D...

Page 10: ...ey recommends additional care and maintenance for the darker colored Terreon For complete instructions on this additional maintenance see Bradley document 1505 Do not use strong acid or alkaline chemi...

Page 11: ...roducts leave a protective coating that helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergent or caustic cleaner Apply in accordance t...

Page 12: ...he battery plug from the adjacent working valve to the problem valve Wait for ten seconds Activate the problem station s sensor ten times The station should turn on If the station turns on and cycles...

Page 13: ...8 307A Valve Body Thru 2 1 269 983 Diaphragm 3 1 269 577 Armature 4 1 269 578 Spring 5 1 269 1729 Armature Housing 6 1 269 1730 Clamp Armature Housing 7 1 269 579 Coil Solenoid Valve 8 3 160 447 Screw...

Page 14: ...ater temperature or temperature fluctuation Hot water supply is not 10 above desired set point Increase hot water supply temperature Valve temperature is not properly set Adjust the temperature as sho...