Troubleshooting BIR3 Components

CAUTION: Turn off water supplies to unit before troubleshooting.

Problem:  An individual operating station drips and fails to shut off.
Cause: 

There is debris trapped between the diaphragm and the valve seat.

Solution:  Remove debris between diaphragm and the valve seat.

Disconnect the plug from the battery to the circuit board of the problem valve . Remove the three #8 Phillips-head screws that 
hold the solenoid valve assembly together . Be careful not to lose the armature or spring . Remove the diaphragm . Remove any 
particles that are trapped between the diaphragm and the valve seat . Rinse off the diaphragm and inspect for damage . Make 
sure the center orifice and both small side orifices are open . Reassemble in reverse order, being careful not to overtighten the 
Phillips-head screws or you may crack the plastic valve body . Tighten until the armature plate makes contact with the plastic 
body . Reconnect the battery plug . Turn on water supplies to the unit .

Problem:  An individual operating station fails to turn on or off.
Cause:  

Excessive line pressure.

Solution:  Install pressure reducing valve.

Check the static line pressure . If the pressure exceeds 80 psi, install a pressure reducer valve at the street main . Excessive line 
pressure (over 60 psi) will shorten the life of any valve .

Problem:  An individual operating station fails to turn on or off.
Cause:  

A dead or faulty battery.

Solution:  Test the station to determine cause and replace battery if required.

CLOSED VALVE

OPEN VALVE

CLOSED VALVE

OPEN VALVE

Disconnect the plug from the battery to the circuit board of the problem valve . 
Disconnect the plug from the battery to the circuit board of an adjacent valve . 
Connect the battery plug from the adjacent working valve to the problem valve . Wait 
for ten seconds . Activate the problem station’s sensor ten times . The station should 
turn on . If the station turns on, and cycles normally, replace the battery .

Cause:  

Faulty sensor eyes.

Solution:  Test station to determine cause; replace sensor eyes if required.

Disconnect the sensor cable from the circuit board of the problem valve . Disconnect 
the sensor cable from the circuit board of an adjacent working valve . Connect the 
sensor cable from the adjacent working valve to the problem valve . Activate the 
problem station’s sensor . The station should turn on . If the station turns on and cycles 
normally, replace the sensor eyes .

Cause:  

Faulty solenoid valve.

Solution:  Test station to determine cause; replace solenoid valve if required.

Remove the screw, circuit board and standoff from the problem valve . Remove the 
battery holder . With a good working battery, briefly contact the solenoid valve directly 
with the battery as shown in Open Valve figure to right . The contact should cause the 
valve to open . With the battery holder removed, briefly contact the solenoid valve with 
the battery in the position shown in Closed Valve figure to right . This should cause 
the valve to close . If the valve does not operate when directly contacted with a good 
battery, and the solenoid valve has already been cleaned as outlined at the beginning 
of this troubleshooting section, replace the solenoid valve .

If problems persist:

Pass your hand in front of the problem station, while at the same time looking to see 
if the indicator light on the circuit board flashes (the indicator light is located near the 
hole in the circuit board where the standoff is mounted) .  If it does not flash, and the 
battery and sensor eyes have already been tested as outlined above, the problem 
may be with the circuit board .  Make a note of the numbers printed on the circuit 
board, then contact your Bradley representative for assistance .

Summary of Contents for Terreon Quadra-Fount MF2944/BIR3

Page 1: ...reater than 80 psi Make sure that all water supply lines have been flushed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction Hardware...

Page 2: ...valve allowing each user to activate a single flow of water Each valve uses less than half the maximum amount of hot water allowed by the ANSI ASHRAE IES 90A 1980 Standard Barrier free and ADA complia...

Page 3: ...S45 2731 optional Stop Hose Valve Assembly with Two Mounting Screws MOUNTING PANELS LOWER BRACKET Parts included with the Quarda Fount Separate all parts from packaging materials and ensure you have a...

Page 4: ...6 OBC 3 1 8 79 JUV 9 1 2 241 STD 8 1 2 216 OBC 5 1 2 140 JUV 5 127 Finished Floor 1 2 Nominal Copper Tubing For Supplies Stub Out Min 1 1 2 from Wall 7 1 2 191 19 1 2 495 1 1 2 NPT Waste Connection Fo...

Page 5: ...ssembly to the wall using appropriate lifting procedures and align the locating notches on the mounting panel with the centerline marked on the wall If the floor is not level install shims under the l...

Page 6: ...s on the side of the left pedestal panel Do not thread the screw completely into the panel but allow 5 16 of the screw to be exposed D Connect the other end of each supply hose to the Navigator TMV va...

Page 7: ...two 3 8 bolts and washers supplied by installer G Fasten the bowl to the upper bracket on the pedestal assembly with the two 1 4 20 x 1 2 round head screws and 5 16 I D washers supplied H Install the...

Page 8: ...right center station to the circuit board attached to the solenoid with the black supply tube D Connect the sensor cable from the left center hand station to the circuit board attached to the solenoid...

Page 9: ...Water in excess of 110 F 43 C may cause scalding H C D Loosen Cap Screw about 4 6 turns and lift up cover do not remove E Using cover turn cartridge gently until desired water temperature is reached D...

Page 10: ...ey recommends additional care and maintenance for the darker colored Terreon For complete instructions on this additional maintenance see Bradley document 1505 Do not use strong acid or alkaline chemi...

Page 11: ...roducts leave a protective coating that helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergent or caustic cleaner Apply in accordance t...

Page 12: ...he battery plug from the adjacent working valve to the problem valve Wait for ten seconds Activate the problem station s sensor ten times The station should turn on If the station turns on and cycles...

Page 13: ...8 307A Valve Body Thru 2 1 269 983 Diaphragm 3 1 269 577 Armature 4 1 269 578 Spring 5 1 269 1729 Armature Housing 6 1 269 1730 Clamp Armature Housing 7 1 269 579 Coil Solenoid Valve 8 3 160 447 Screw...

Page 14: ...ater temperature or temperature fluctuation Hot water supply is not 10 above desired set point Increase hot water supply temperature Valve temperature is not properly set Adjust the temperature as sho...

Reviews: