Bradley Terreon Quadra-Fount MF2944/BIR3 Installation Manual Download Page 1

Installation

MF2944/BIR3

Terreon

®

 Quadra-Fount

™ 

Washfountain 

with Battery Operated Infrared Control

(Standard*, Juvenile and OBC Height)

* Standard Height is ADA/TAS Compliant

IMPORTANT!

Read this entire installation manual to ensure proper installation. When 

finished with the installation, file this manual with the owner or maintenance 

department.

Separate parts from packaging and make sure all parts are accounted for 

before discarding any packaging material. If any parts are missing, do not 

begin installation until you obtain the missing parts.

Water supply requires a flowing pressure of at least 20 psi, but no greater 
than 80 psi. 

Make sure that all water supply lines have been flushed and then completely 
turned off before beginning installation. Debris in supply lines can cause 
valves to malfunction.

Hardware supplied by installer must be appropriate for wall construction. Wall 

anchors used must have a minimum pull-out rating of 1,000 lbs.

Product warranties may be found under “Product Information” on our web site 

at www.bradleycorp.com.

THIS

SIDE

UP

Packing List

Installation

Table of Contents

Pre-Installation Information   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Parts Included with the Quadra-Fount

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Installation Instructions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .4-9
Cleaning and Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .10-11
Troubleshooting .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .12-14

215-1373 Rev. P; ECN 14-00-006
© 2014 Bradley
Page 1 of 14 

6/6/2014

P .O . Box 309, Menomonee Falls, WI  53052-0309
Phone: 1-800-BRADLEY  Fax: (262) 251-5817
http:\\www .bradleycorp .com

Summary of Contents for Terreon Quadra-Fount MF2944/BIR3

Page 1: ...reater than 80 psi Make sure that all water supply lines have been flushed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction Hardware...

Page 2: ...valve allowing each user to activate a single flow of water Each valve uses less than half the maximum amount of hot water allowed by the ANSI ASHRAE IES 90A 1980 Standard Barrier free and ADA complia...

Page 3: ...S45 2731 optional Stop Hose Valve Assembly with Two Mounting Screws MOUNTING PANELS LOWER BRACKET Parts included with the Quarda Fount Separate all parts from packaging materials and ensure you have a...

Page 4: ...6 OBC 3 1 8 79 JUV 9 1 2 241 STD 8 1 2 216 OBC 5 1 2 140 JUV 5 127 Finished Floor 1 2 Nominal Copper Tubing For Supplies Stub Out Min 1 1 2 from Wall 7 1 2 191 19 1 2 495 1 1 2 NPT Waste Connection Fo...

Page 5: ...ssembly to the wall using appropriate lifting procedures and align the locating notches on the mounting panel with the centerline marked on the wall If the floor is not level install shims under the l...

Page 6: ...s on the side of the left pedestal panel Do not thread the screw completely into the panel but allow 5 16 of the screw to be exposed D Connect the other end of each supply hose to the Navigator TMV va...

Page 7: ...two 3 8 bolts and washers supplied by installer G Fasten the bowl to the upper bracket on the pedestal assembly with the two 1 4 20 x 1 2 round head screws and 5 16 I D washers supplied H Install the...

Page 8: ...right center station to the circuit board attached to the solenoid with the black supply tube D Connect the sensor cable from the left center hand station to the circuit board attached to the solenoid...

Page 9: ...Water in excess of 110 F 43 C may cause scalding H C D Loosen Cap Screw about 4 6 turns and lift up cover do not remove E Using cover turn cartridge gently until desired water temperature is reached D...

Page 10: ...ey recommends additional care and maintenance for the darker colored Terreon For complete instructions on this additional maintenance see Bradley document 1505 Do not use strong acid or alkaline chemi...

Page 11: ...roducts leave a protective coating that helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergent or caustic cleaner Apply in accordance t...

Page 12: ...he battery plug from the adjacent working valve to the problem valve Wait for ten seconds Activate the problem station s sensor ten times The station should turn on If the station turns on and cycles...

Page 13: ...8 307A Valve Body Thru 2 1 269 983 Diaphragm 3 1 269 577 Armature 4 1 269 578 Spring 5 1 269 1729 Armature Housing 6 1 269 1730 Clamp Armature Housing 7 1 269 579 Coil Solenoid Valve 8 3 160 447 Screw...

Page 14: ...ater temperature or temperature fluctuation Hot water supply is not 10 above desired set point Increase hot water supply temperature Valve temperature is not properly set Adjust the temperature as sho...