Express® Lavatory System SS-Series
Installation - Obsolete
SS-3/AZ/WH97TAS
9
Bradley Corporation • 215-1175 Rev. H; EN 08-805
4/24/08
Installation Instructions continued . . .
Step 4: Connecting supply, drain, and electrical
1. FOR HOT AND COLD SUPPLIES: Connect the flexible hoses installed to the Vernatherm™
Mixing Valve to the hot and cold water supply piping from the wall (see Figure 6a).
Note: The red marking on Vernatherm™ Mixing Valve indicates hot water supply inlet.
FOR SINGLE TEMPERED SUPPLY: Attach the stop/strainer/check valve to the 1/2" tempered
supply line. Attach the 3/8" tube from the sprayhead to the 90° elbow located on the
stop/check/strainer (see Figure 6b).
2. Insert the plastic tubing from the bowl assembly into the Vernatherm™ Mixing Valve.
3. Assemble the P-trap (supplied) and make drain connections.
IMPORTANT: The Express® must be connected to the 24 VAC Class II plug-in
transformer provided. Connection to 110 VAC can result in damage
to the electronics and cause personal injury.
4. Plug in the 24 VAC Class II transformer (supplied) into the 110 volt electrical outlet.
STOP/STRAINER/CHECK
VALVE
ELBOW 90°,
3/8" TUBE
ELBOW
Figure 6b
Figure 6a
PLASTIC
TUBING
VERNATHERM™
THERMOSTATIC
MIXING VALVE
FLEXIBLE
SUPPLY
HOSE
CONNECT
TO 1/2"
NPT COLD
WATER
SUPPLY
CONNECT
TO 1/2" NPT
HOT WATER
SUPPLY
3/8" FEMALE
CONNECTOR
FLEXIBLE
SUPPLY