Express® Lavatory System SS-Series
Installation - Obsolete
SS-3/AZ/WH97TAS
17
Bradley Corporation • 215-1175 Rev. H; EN 08-805
4/24/08
THEN
Valve Position is
Hot Supply
Cold Supply
Valve Delivers
Correct
Hot
Cold
Mixed 107°
Correct
Hot
No Water
Valve shuts off or drips
Correct
No Water
Cold
Valve shuts off or drips
Correct
Hot
Hot
Hot
Correct
Cold
Cold
Cold
Reversed
Hot
Cold
Cold/below 107° Hot/above 107°
Reversed
Hot
No Water
Hot
Reversed
No Water
Cold
Cold
Reversed
Hot
Hot
Hot
Reversed
Cold
Cold
Cold
Vernatherm™ Mixing Valve Maintenance and Service
*Repair kit S45-049 is pre-packaged and includes O-Ring, Flip Ring, Power Element and Spring.
Maintenance Instructions
1. Disassemble the Vernatherm™ Valve as shown,
being careful not to damage the power element.
Replace the element, if necessary.
2. If necessary, remove the old flip ring and replace
with a new ring.
NOTE: An old or worn flip ring may cause temperature
fluctuation and/or water chatter.
3. Reassemble the power element and valve body.
Apply grease to the main valve slide and gently ease
into position, rotating so that grease is applied to the
flip ring. Do not force the slide as this may push the
flip ring from its position. To test, rotate the slide; a
slight drag should be felt when correctly installed.
4. Reassemble the valve.
Service Suggestions
When servicing the valve, make sure it is installed in the correct position. The most common error
occurs when the valve is installed in the reversed position, that is, the hot line is connected to the cold
line and the cold is connected to the hot.
NOTE: A red marking indicates the hot side of the valve.
The table below lists conditions that occur when the valve is installed correctly, and when it is in the
reversed position.
Flip Ring*
125-015
Power Element*
S27-019
Valve Slide
S01-039
Spring*
135-008
O-Ring*
125-001CH
Screw
160-175
Body
S73-027
Body (chrome)
S73-028
Cover
107-261B
IF