Express
®
Lavatory System - MG-Series with TouchTime
®
Control
MG-2/TT
Installation
6
4/9/2014
Bradley
• 215-1480 Rev. G; ECN 13-08-025
Figure 1a
TAS - Texas Accessibility
Standards:
Juvenile Height (grades
Pre-K thru 5 or 6)
4"
(102
)
5"
(127
)
FLOOR
14"
(356)
14"
(356
)
18
⁷⁄₈
"
(479
)
24¾"
(629
)
22¼"
(565
)
½" NOMINAL COPPER TUBING FOR HOT AND COLD SUPPLIES OR
TEMPERED SUPPLY – STUB OUT 2"
³⁄₈
" WALL ANCHORS (8) PLACES MIN. PULL-OUT STRENGTH 1000 LBS. PER ANCHOR
CENTERLINE OF FIXTURE
1½" NPT DRAIN
STUB OUT 2"
21"
(533
)
22½"
(572
)
28"
(711
)
3¾" (95
)
16"
(406
)
4"
(102
)
4" (102
)
RECOMMENDED 240V/208V
OR 277V FOR OPTIONAL
ELECTRICAL BOX
LOCATION
(2½" l x 3" w x 4" h)
RECOMMENDED
240V/208V OR 277V
FOR OPTIONAL
ELECTRICAL BOX
LOCATION
(4" l x 3" w x 4" h)
19½"
(495
)
H
C
16½"
(419
)
APPROX. DIMENSION
25½" (648)
APPROX. DIMENSION
25½" (648)
A
A
B
B
B
B
B
B
Figure 1b
TAS - Texas Accessibility
Standards:
Juvenile Height (grades 6
thru 8 or 9)
4"
(102
)
5"
(127
)
FLOOR
14"
(356)
14"
(356
)
26-3/4"
(679
)
24-1/4"
(616
)
½" NOMINAL COPPER TUBING FOR HOT AND COLD SUPPLIES OR TEMPERED
SUPPLY – STUB OUT 2"
³⁄₈
" WALL ANCHORS (8) PLACES MIN. PULL-OUT STRENGTH 1000 LBS. PER ANCHOR
CENTERLINE OF FIXTURE
1½" NPT DRAIN
STUB OUT 2"
23"
(584
)
3¾" (95
)
18"
(457
)
4"
(102
)
4" (102
)
RECOMMENDED 240V/208V
OR 277V FOR OPTIONAL
ELECTRICAL BOX
LOCATION
(2½" l x 3" w x 4" h)
RECOMMENDED
240V/208V OR 277V
FOR OPTIONAL
ELECTRICAL BOX
LOCATION
(4" l x 3" w x 4" h)
21½"
(546
)
H
C
16-1/2"
(419
)
APPROX. DIMENSION
25½" (648)
APPROX. DIMENSION
25½" (648)
A
A
B
B
B
B
B
B
30"
(762
)
20
⁷⁄₈
"
(530
)
24½"
(622
)
110V GFI
PROTECTED
ELECTRICAL
OUTLET
110V GFI
PROTECTED
ELECTRICAL
OUTLET