Express
®
Lavatory System - MG-Series with TouchTime
®
Control
Installation
MG-2/TT
Bradley
• 215-1480 Rev. G; ECN 13-08-025
4/9/2014
5
Installation Instructions
Step 1: Rough in supplies and optional hot water heater
NOTE: See Figure 1 (below), 1a, 1b (for TAS on page 6) and Figure 2 (on page 7) when roughing
in the MG-2/TT Express
®
.
IMPORTANT: Flush the supply lines before making connections. Debris in supply lines will cause
the valves to malfunction.
IMPORTANT: Dimensions shown in Figure 1 are for Standard Height Mounted
MG-2/TT Express
®
.
1. Rough in
½
" nominal copper tubing for hot and cold supply lines through wall at dimensions shown.
2. Rough in 1
½
" NPT drain waste connection through wall at dimensions shown.
3. OPTIONAL HOT WATER HEATER: Rough in appropriate electrical supply per local code (recommended
240/208-volt or 277-volt electrical box location shown below).
4"
(102
)
5"
(127
)
FLOOR
14"
(356)
14"
(356
)
*22³
⁄₈
"
(568
)
*28¼"
(718
)
*25¾"
(654
)
½" NOMINAL COPPER TUBING
FOR HOT AND COLD SUPPLIES OR
TEMPERED SUPPLY – STUB OUT 2"
³⁄₈
" WALL ANCHORS (8) PLACES MIN. PULL-OUT
STRENGTH 1000 LBS. PER ANCHOR
110V GFI
PROTECTED
ELECTRICAL
OUTLET
*Juvenile Height Mounting:
Subtract 4" from vertical dimensions for compliance with ADA guidelines for children’s use.
Figure 1
Standard Height Mounting
CENTERLINE
OF FIXTURE
1½" NPT DRAIN
STUB OUT 2"
*24½"
(654
)
*26"
(660
)
*31½"
(800
)
3¾" (95
)
*19½"
(495
)
4"
(102
)
4" (102
)
RECOMMENDED 240V/208V
OR 277V FOR OPTIONAL
ELECTRICAL BOX
LOCATION
(2½" l x 3" w x 4" h)
RECOMMENDED
240V/208V OR 277V
FOR OPTIONAL
ELECTRICAL BOX
LOCATION
(4" l x 3" w x 4" h)
*23"
(584
)
H
C
16½"
(419
)
APPROX. DIMENSION
25½" (648)
APPROX. DIMENSION
25½" (648)
A
A
B
B
B
B
B
B