3
Installation - For Service Only
S53-302
Bradley Corporation • 215-1525 Rev. G; EN 07-209
7/23/07
Installation
Supplies required:
• Mounting screws for operation
box
• Pipe sealant
• 1/2" NPS water inlet supply
• Pipe fittings
• OPTIONAL: 100–240 VAC
adapter (plug-in adapter
available from Bradley)
Step 1: Mount the Faucet
1. Select the location on the deck
where the faucet will be
mounted.
2. Drill a 1-1/4" (32mm)
diameter mounting hole in the
deck (to allow for clearance of
the mounting nut and sensor
cable).
3. OPTIONAL TRIMPLATE:
• Drill two 3/8" (10mm) dia.
mounting holes on the deck
as shown The holes should
be spaced 4" (102mm) apart
(measured from center to
center) and aligned with the
faucet mounting hole.
• Thread the studs into the bottom of the trimplate.
• Insert the trimplate studs into the deck holes and position the plate onto the deck. Secure the
plate to the deck with the two 3/8" hex nuts and U-brackets provided.
• Thread the two small anti-rotational mounting screws into the two holes in the underside of the
trimplate and into the two holes in the bottom of the faucet body.
Make sure screws are aligned
with all holes.
4. Gently insert the faucet stud and sensor cable through the center hole in the deck.
NOTE: Take care not to pinch the sensor cable.
5. Position the brass mounting washer onto the stud from beneath the deck. The sensor cable should
be free from contact with the brass mounting washer. Screw the hex nut onto the faucet stud and
secure the faucet to the deck by tightening the nut.
Figure 1
FAUCET
RUBBER
GASKET
SENSOR
CABLE
FAUCET
STUD
TRIMPLATE
TRIMPLATE
STUD (qty. 2)
BRASS
MOUNTING
WASHER
NUT
3/8" DIA.
HOLE
1-3/4" DIA.
HOLE
DECK
U-BRACKET
ANTI-ROTATIONAL
MOUNTING SCREW (qty. 2)