28
VI - TROUBLESHOOTING
(cont.)
Thermal Fuse:
Wire color
Voltage
Resistance
Connector #
Pin #’s
Red ~ Red
100 VAC
Below 1 ohm
B ~ C
B6 ~ C1
Overheat Switch:
Red ~ Red
100 VAC
Below 1 ohm
B ~ C
B6 ~ C1
Flame Rod:
Place one lead of your meter to the flame rod and the other to earth or ground. With the unit running
you should read between 5 ~ 150 VAC. Set your meter to the µ amp scale, series your meter in line
with the flame rod. You should read1µ or greater for proper flame circuit. In the event of low flame
circuit remove the flame rod and check for carbon and/or damage.
Heat Exchanger, Air Temperature, and Outgoing Water Temperature Thermistors:
Check all thermistors by inserting meter leads into each end of the thermistor plug. Set your meter to
the 20K scale and read resistance. You should be able to apply heat to the thermistor bulb and see
the resistance decrease. Then apply some ice to the thermistor and the resistance should increase.
See below for examples of temperatures and resistance reading at those temperatures.
Example:
59ºF = 11.4 ~ 14K
86ºF = 6.4 ~ 7.8K
113ºF = 3.6 ~ 4.5K
140ºF = 2.2 ~ 2.7K
221ºF = 0.6 ~ 0.8K
Outgoing Water Thermistor:
White ~ White
N/A
See example above
B4
B3 ~ B4
Heat Exchanger Temperature Thermistor:
White ~ Pink
N/A
See example above
B5
B3 ~ B12
Air Temperature Thermistor:
White ~ Orange
N/Asee example above
B1
B2 ~ B11
Surge Protector:
Black ~ White
108 ~ 132 VAC
N/A
Surge Protector D
1
1 ~ 3
Blue ~ Brown
108 ~ 132 VAC
N/A
Surge Protector D
2
1 ~ 2
Remote Controls:
Terminals D
1
10 ~ 13 VDC digital
1.5K ~ 1.9K ohms
H
1 ~ 3
Frost Protection:
This unit has four frost protection heaters mounted at different points inside the unit to protect the
water heater from freeze ups. There are two heaters located on the outlet hot water line next to the
thermistor. Using a voltage meter set on the 200 ohm scale, you should have a resistance reading of
26 ~ 30 ohms through each of these heaters. The heater located on the heat exchanger piping
should have a resistance reading of 81 ~ 86 ohms and the one located in the water flow sensor valve
has a resistance reading of 16 ~ 19 ohms. Voltage throughout this circuit should be 120 VAC.
Summary of Contents for Everhot IGI-180C-5N
Page 7: ...I GENERAL INFORMATION cont CUT AWAY ILLUSTRATION 7...
Page 8: ...I GENERAL INFORMATION cont SCHEMATIC ILLUSTRATION 8...
Page 21: ...V SEQUENCE OF OPERATION cont Operation Sequence Flow Chart 21...
Page 22: ...V SEQUENCE OF OPERATION cont Operation Sequence Flow Chart 22...
Page 23: ...V SEQUENCE OF OPERATION cont Sequence Timing Chart 23...
Page 24: ...V SEQUENCE OF OPERATION cont Sequence Timing Chart 24...
Page 30: ...Wiring Schematic 30...
Page 55: ...55 X PARTS BREAKDOWN Disassembled View Cabinet...
Page 56: ...X PARTS BREAKDOWN Disassembled View Internals 56...
Page 57: ...X PARTS BREAKDOWN Disassembled View Internals 57...
Page 58: ...X PARTS BREAKDOWN Disassembled View Electrical 58...
Page 62: ...62 Notes...
Page 63: ...63 Notes...