II - SPECIFICATIONS
(cont.)
DIP SWITCH SETTINGS
DANGER
Do not attempt to adjust dip switch settings from there factory default settings.
Doing so will result in damage to unit, property damage, personal injury or death.
Contact Technical Support for information pertaining to dip switch function.
FACTORY DEFAULT SETTING, RESIDENTIAL UNITS
Natural Gas
Propane Gas
Dip Switch Settings:
Dip Switch Settings:
(SW1)
(SW2)
(SW1)
(SW2)
#1 = Off
#1 = On
#1 = Off
#1 = Off
#2 = On
#2 = Off
#2 = On
#2 = Off
#3 = Off
#3 = Off
#3 = Off
#3 = Off
#4 = Off
#4 = Off
#4 = Off
#4 = Off
#5 = Off
#5 = Off
#6 = Off
#6 = Off
#7 = Off
#7 = Off
#8 = Off
#8 = Off
FACTORY DEFAULT SETTING, COMMERCIAL UNITS
Natural Gas
Propane Gas
Dip Switch Settings:
Dip Switch Settings:
(SW1)
(SW2)
(SW1)
(SW2)
#1 = Off
#1 = On
#1 = Off
#1 = Off
#2 = On
#2 = Off
#2 = On
#2 = Off
#3 = Off
#3 = Off
#3 = Off
#3 = Off
#4 = Off
#4 = On
#4 = Off
#4 = On
#5 = Off
#5 = Off
#6 = Off
#6 = Off
#7 = Off
#7 = Off
#8 = Off
#8 = Off
See page 13 for special dip switch settings base on vent length.
12
Summary of Contents for Everhot IGI-180C-5N
Page 7: ...I GENERAL INFORMATION cont CUT AWAY ILLUSTRATION 7...
Page 8: ...I GENERAL INFORMATION cont SCHEMATIC ILLUSTRATION 8...
Page 21: ...V SEQUENCE OF OPERATION cont Operation Sequence Flow Chart 21...
Page 22: ...V SEQUENCE OF OPERATION cont Operation Sequence Flow Chart 22...
Page 23: ...V SEQUENCE OF OPERATION cont Sequence Timing Chart 23...
Page 24: ...V SEQUENCE OF OPERATION cont Sequence Timing Chart 24...
Page 30: ...Wiring Schematic 30...
Page 55: ...55 X PARTS BREAKDOWN Disassembled View Cabinet...
Page 56: ...X PARTS BREAKDOWN Disassembled View Internals 56...
Page 57: ...X PARTS BREAKDOWN Disassembled View Internals 57...
Page 58: ...X PARTS BREAKDOWN Disassembled View Electrical 58...
Page 62: ...62 Notes...
Page 63: ...63 Notes...