IGI – 7. Removal of Transformer:
CAUTION
120 volt potential exposure. Isolate the appliance and
reconfirm power has been disconnected using a multi-
meter.
a.
Remove the combustion fan motor assembly
as described in IGI - 5 a,b.
b.
Remove the two (2) Phillips screws to release
the transformer.
c.
Disconnect wiring harness connectors to
transformer and pull out towards you.
IGI – 8. Removal of Burner Manifold and the Burner:
CAUTION
120 volt potential exposure. Isolate the appliance and
reconfirm power has been disconnected using a multi-
meter.
a.
To remove the burner manifold, remove (6)
Phillip screws around the burner plate as
shown in the upper right picture.
b.
Remove the (3) Phillip screws at the gas valve
assembly.
c.
Grip the burner manifold and remove it from
the unit.
d.
To remove the burner assembly remove
(8) Phillip screws around the sight glass
panel. Remove this panel.
e.
Locate the (2) Phillip screws inside the
burner chamber that hold the burner
assembly in place. Remove these two
screws, grip the burner assembly and
slide it out of the combustion housing.
f.
If you need to remove each burner from
this housing remove the (2) Phillip screws
on each side of the burner, as shown
below.
51
Summary of Contents for Everhot IGI-180C-5N
Page 7: ...I GENERAL INFORMATION cont CUT AWAY ILLUSTRATION 7...
Page 8: ...I GENERAL INFORMATION cont SCHEMATIC ILLUSTRATION 8...
Page 21: ...V SEQUENCE OF OPERATION cont Operation Sequence Flow Chart 21...
Page 22: ...V SEQUENCE OF OPERATION cont Operation Sequence Flow Chart 22...
Page 23: ...V SEQUENCE OF OPERATION cont Sequence Timing Chart 23...
Page 24: ...V SEQUENCE OF OPERATION cont Sequence Timing Chart 24...
Page 30: ...Wiring Schematic 30...
Page 55: ...55 X PARTS BREAKDOWN Disassembled View Cabinet...
Page 56: ...X PARTS BREAKDOWN Disassembled View Internals 56...
Page 57: ...X PARTS BREAKDOWN Disassembled View Internals 57...
Page 58: ...X PARTS BREAKDOWN Disassembled View Electrical 58...
Page 62: ...62 Notes...
Page 63: ...63 Notes...