73
Installation Guidelines
Mechanical Part:
Attachment is by at least 2 holes provided on the housing with
M 8 bolts and a tightening torque of 15 Nm (13.5 - 16.5 Nm).
The installation site must be chosen so that the COLAS
®
+ valve
is protected from spray or high pressure wash water. Good
accessibility to the operating lever must be provided. Ensure that
the unit does not protrude outside the overall vehicle width. The
vehicle manufacturer must provide suitable protection against
unauthorised activation.
Electrical Part:
Bayonet connection according to DIN 72585. For the bayonet
connection, turn the union nut clockwise to make certain that
it is correctly attached and locks in to ensure optimum sealing.
An electrical connection to the solenoid valve is permissible only
via the ECO Tronic EBS-ECU, which provides a signal „Reset
to ride height“. BPW Bergische Achsen is not liable for other
types of actuation.
Operating pressure:
p
e
max. 8.5 bar
Operating temperature:
- 40° C to +80°C
Weight:
approx.
1.5
kg
Solenoid Valve:
perm. duty cycle
10 s
Voltage
U
B
= 24 VDC +7/-8
Current / Output
lo= 250 mA / Po = 6 W
Protection class
DIN 40050 - IP 6
K
9
K
Fig. 130
Fig. 129
Technical Data
Electrical Connection
5.2 Air suspension
5.2.4 COLAS
®
+
94.5
37
32
26
38
6
10.5
33
54
134
205
121
30
53
1
12
11
3
12
1
21
22
39.5
34.5
86
Re
s
t Po
s
ition Lower
94
S
top Po
s
ition
110
Travel Po
s
ition
4x Ø 9.5
4x M 8
Ø 36
Ø 44
270
177
160
Te
s
t point
56.6
50
56.6
Summary of Contents for ECO Tronic EBS
Page 2: ...2 BPW Operating and Installation Instructions...
Page 47: ...47...
Page 90: ...90...
Page 98: ...98 Notice...
Page 99: ...99...