27
7
-
CUSTOMIZATION OF THE TEMPERATURE
LEVELS FOR THE HEATING PROGRAMME
7.1-
Extract the unit body.
7.2-
Make sure that the symbol for the heating pro-
gramme is active , and if necessary press the button
(fig. 41).
7.3-
Press button
P
(fig. 42).
You will see the temperature range for 1, the indication
in place of the current time and the value of the temperature
assigned to range T1 (set in memory at16 °C).
7.4-
Set the desired temperature for T1 using the button
or (fig. 43).
7.5-
Press button
P
to confirm the temperature shown
on the display and to move on the next temperature
level (fig. 44).
Note. The value assigned to each temperature range is
limited to the values of the range just above or below. For
example, if range T3 corresponds to 20 °C and rangeT1
corresponds to 16 °C, the value for rangeT2 may vary
41
39
40
42
TH350 EN 05_08.indd 27
TH350 EN 05_08.indd 27
30-05-2008 8:20:52