even  in  the  room  preventing  UVA/UVB  and  keep  along  3  to  6  months 
because  of  the  treatment  skin  sensitivity  to  the  sunlight.  Using  suntan 
lotion or umbrella preventing can improve the effect early. 

6) 

Period  for  laser  treatment:  According  to  the 

different treatment parts and 

7) 

pigment dark or not, the treatment may be several 

times. Normally one period of treatment is 1-2 times, every time at 20-30 
days  interval.  If  there  is  no  special,every  2-4  weeks  go  to  clinic  check 
again, if there is anything abnormally, please cure it early. 

8) 

Pigment  fadeaway  is  a  slow  process,  for  the 

pigmentation skin, normally it is 1-3 months. In order to get more favorable 
effect, repeated treatment should be 1-3 months interval. 

 
 

Maintenance: 

1) 

Notice  to  use  purified  water  or  de-ionized  water, 

not the mineral water or tap water. 

2) 

Be  careful  not  to  irradiate  the  machine  avoiding 

the surface of machine injured. 

 

 

Common Questions and Fixing: 

1) 

No  signal  after  power  on.  The  reason  is  that  the 

power plug doesn‟t reach it,please directly connect the power plug. 

2) 

No  signal  after  power  on  because  of  the  fuse 

blowing. Please replace the fuse with 5A/220V AC. 

3) 

No  signal  on  the  screen  because  that  the 

Crash-stop  switch  being  pressed.  Please  lift  the  Emergency-stop  switch 
up. 

4) 

Touch-off  light  is  off  state  pressing  the  button  on 

the  screen  when  the  machine  is  on  pre-ignition.  One  reason  is  that  the 
Xenon  Lamp  is  damaged  need  to  replace  a  new  one.  Another  reason  is 
that the life time for Xenon is full, change a new one. 

5) 

Water  leaking  out  of  machine,  because  of  the 

impact during on shipment 
process. May in the tube joint. Please call the service people to deal with it. 

6) 

If  you  feel  the  energy  is  not  big  enough  or  the 

curing treatment is not well enough, the reason maybe the temperature is 
too  higher  or  no  water  in  the  machine  and  damaged  the  body  machine. 
Please stop firstly, after half an hour starting the machine again. 

 
 

 

Summary of Contents for HL-A04

Page 1: ...Co ltd ADD RM902 ShangMei Times NO 57 LongGuan RD Long Hua Dist Shenzhen China 518000 Tel 86 755 29994192 13148703639 Email sales bowei ch com http www bowei ch com Laser Tattoo Removal System Model HL A04 Operation Manual ...

Page 2: ...sales bowei ch com http www bowei ch com CONTENT 1 Important Notice 2 Technical Specifications 3 Accessories 4 Product Features 5 Working principle 6 Operations 7 Operation skills for laser tattoo removal system 8 Requirement before treatment 9 Before after treatment by laser 10 Maintenance 11 Common Questions and Fixing 12 Special illustration ...

Page 3: ...r to the standard line on the water tank Prohibit to work without water Otherwise if shatter the laser head the user bear it 5 Avoid irradiation to eyes directly 6 Forbid disassembling without manufacture permission 7 Put the head light on fixture avoid broken after operation 8 Change cooling water every month Long or short the time according to the water purity 9 Start up the machine after one mi...

Page 4: ...en Bowei tech Co ltd ADD RM902 ShangMei Times NO 57 LongGuan RD Long Hua Dist Shenzhen China 518000 Tel 86 755 29994192 13148703639 Email sales bowei ch com http www bowei ch com Gross Weight 17kg Accessories ...

Page 5: ... the efficiency and make the best solutions for no burning on the hand piece at all 2 Long lifetime for Xenon Lamp which is with the imported US technology 3 More stability with the hand piece structure inside improved 4 Add the infrared Guide light to aim the target tissue correctly 5 Portable design and easy operation can do the touring treatment lower cost and wider usage can make quick return ...

Page 6: ... device please wait till dry then input water to test Keep 22 28 temperature and the humidity not more than 20 in the treatment room b Input water water source pure water or distilled water a Screw off the screw caps of water inlet and spilt water orifice at the same time b Connect the water tube and water funnel well and insert the orifice to input water c Automatic water spilt from the spilt wat...

Page 7: ...7 LongGuan RD Long Hua Dist Shenzhen China 518000 Tel 86 755 29994192 13148703639 Email sales bowei ch com http www bowei ch com c Join one end of the handle to the joint show as follows d Join the power line and the pedal line then turn on the power source ...

Page 8: ...he water doesn t cycle inside the device or the probe does not cold it s possible that there is air in the pump At this moment please turn on the device when turn to the welcome screen do not do any operation on the screen at the moment then fold the white hose in handle to the angle of 90 degrees and slack then turn off the device repeat this action for 3 6 times That could exhaust the air to the...

Page 9: ...ser Treatment Mode Selection Interface Fig 2 The Laser Treatment Mode Selection Interface provides six kinds of treatment modes for different parts of body for clients selection When it needs to return from Laser Treatment Interface Fig 3 to Laser Treatment Mode Selection Interface after completing the treatment the system will automatically record the treatment parameters laser energy and bright ...

Page 10: ...ment Interface and wait for three seconds press the work key to make it change into orange Press the working button on the treatment end and there will be laser output and will show on the screen at the same time representing to output the laser now while represents no laser to output now Press the cease key after the treatment is finished and the system will automatically zero clear the current c...

Page 11: ...he greater the laser output energy is which could adjust according to the actual situation 2 Laser working frequency adjustment The laser working frequency scope is 1 6 Hz to adjust its size through the up and down arrows If always press the adjustment button the laser working frequency will automatically increase or decrease The adjustment step length of the laser working frequency is 1 Hz The bi...

Page 12: ... the icon represents that the bare head has not been lit After the bare head is lit it could enter into the charged status If it does not light the bare head for five seconds then return to the ready mode Charged status The icon represents successful charge while the icon represents unsuccessful charge Only after the successful charge could it enter into the treatment status for treatment If the c...

Page 13: ...ss or become swollen which is a role of heat that will promote collagen re growth Pay attention do not make ice cooling at this time just wait for 20 60 minutes they will be gradually disappeared 2 The skin is very dry so you have to pay more attention to keep moisture of skin 3 Some people will have a little allergic to carbon powder you can rub some external medicine Cosmetic and skin care produ...

Page 14: ...ck the language selection button it will pop the language selection dialog box Directly click the required language icon to alter the system language The default system provides two languages of Spanish and English 2 Alter the system password Click the password change button to switch to System Password Change Display Interface Fig 14 It is OK to directly enter through the keyboard The green passw...

Page 15: ...the backstage password shown in Fig 15 The default backstage password out of factory is 666666 which could be changed according to the demand The change method could reference System Password Change If input the correct password it will enter Backstage Setup Interface Fig 16 The backstage setup interface could conduct the operation including zero clearing the treatment ends counter encrypting the ...

Page 16: ...counter and switch to Counter Encryption Interface Fig 17 Directly enter the counter s protection password and restricted times through the keyboard Under the encryption status of the counter the counter will automatically deduce one for each use of the treatment end When the counter is zero the treatment end will not be used again If it needs to cancel the counter s encryption status it could cli...

Page 17: ... stop working and it should immediately stop the machine and restart after removing the faults Operation skills for laser tattoo removal system Items times interval Notice eyebrow 1 2 30 60day Remove eyebrow hair and protect eyeballs eyelid 1 3 45 60day Remove eyebrow hair and protect eyeballs lips outline 1 3 15 45day use 532mn mirror Body tattoo 1 4 30 60day Exude blood is effective flecks aged ...

Page 18: ...lly about 2 days Taking some Vitamins can lighten the pigment circumfluence Usually there is a feeling of scorching or slight bleeding it is normal and no scar 3 When the scabs fade away the treatment part shows pink 2 3 weeks later it appears coffee color and 1 2 months later recover 3 Care after treatment 1 Can wash the skin with water or Non stimulator after treatment 2 If there is slight bleed...

Page 19: ... ionized water not the mineral water or tap water 2 Be careful not to irradiate the machine avoiding the surface of machine injured Common Questions and Fixing 1 No signal after power on The reason is that the power plug doesn t reach it please directly connect the power plug 2 No signal after power on because of the fuse blowing Please replace the fuse with 5A 220V AC 3 No signal on the screen be...

Page 20: ... or purchase please contact with the company 2 for the following user personal causes of the fault does not provide free maintenance warranty service 1 to tear open outfit modified the products caused by the fault 2 the use of the company caused by the distribution of the adapter failure 3 careless use throw drop caused by the fault 4 the fault caused by the lack of reasonable maintenance 5 not ac...

Reviews:

Related manuals for HL-A04